background image

1-4(E)

BKSI-2010

2. Information of BKSI-2010

2-2.

Connector Panel Installation

General information for installation

• The connector panel is inserted into the slot with the

same number as the plug-in board installed in the front
of SIU-80.

• The model label supplied with the BKSI-2010 is at-

tached in the chassis to prevent the panel inserting into
the incorrect slot when the connector panel replacement
and others.

w

Do not install with turning the power on

Touching the power contact portion or the primary wind-
ing circuit may cause electric shock.
For safety reason, turn off the power and unplug the
appliance from the outlet before starting the installation.

Procedures

1.

Turn off the power of SIU-80 and unplug the appli-
ance from the outlet.

2.

Remove the rear blank panel. (Refer to the Installation
Manual supplied with the SIU-80.)

3.

Attach the model label supplied with the BKSI-2010 in
the chassis near the slot to install the board.

n

After the connector panel is inserted into a slot, the
model label cannot be seen.

4.

Insert the connector panel to the matching slot and fix
the panel by the two screws securing the rear blank panel.

Connector panel removal

1.

Turn off the power of SIU-80 and unplug the appli-
ance from the outlet.

2.

Remove the two screws securing the connector panel
and remove the connector panel.

m

• When removing the connector panel, move the panel

to the right and left slowly until the connection with
the mother board is sufficiently loose, then remove
the connector panel slowly.

• Panels must be held by the plugs of the cables which

are connected to the BNC cables.

2-3.

Notice in Power on

After installing BKSI-2010 into SIU-80, turn on the power
of SIU-80.
Before turning on the power of SIU-80, always make sure
that the power of the disk drives is set to off.  If the power
of the disk drive is turned on before SIU-80, an error may
occur in the disk drives.
If so, turn off the power of SIU-80 first, and next the disk
drives.
Then, turn on the power in the sequence of SIU-80 and
disk drives.

SIU-80

Rear blank panel

BVTT 3

×

6

SIU-80

BVTT 3

×

6

Connector panel

Model label

Summary of Contents for BKSI-2010

Page 1: ...INSTALLATION MANUAL 1st Edition Revised 2 Serial No 10001 and Higher BKSI 2010 Serial No 10001 and Higher BKSI 2011 DISK CONTROLLER MEMORY BOARD BKSI 2011 DISK CONTROL BOARD BKSI 2010 ...

Page 2: ...ertes Fachpersonal bestimmt Alle Wartungsarbeiten dürfen nur von qualifiziertem Fachpersonal ausgeführt werden Um die Gefahr eines elektrischen Schlages Feuergefahr und Verletzungen zu vermeiden sind bei Wartungsarbeiten strikt die Angaben in der Anleitung zu befolgen Andere als die angegeben Wartungsarbeiten dürfen nur von Personen ausgeführt werden die eine spezielle Befähigung dazu besitzen AVE...

Page 3: ...nstallation 1 3 2 2 Connector Panel Installation 1 4 2 3 Notice in Power on 1 4 2 4 Location and Function of Connectors 1 5 2 5 Connecting Connector and Cable 1 6 2 6 Signal Input Output 1 6 2 7 Location and Function of Switches LEDs 1 8 2 7 1 SCS 4 Board 1 8 2 7 2 IO 116 Board 1 9 2 8 NOVRAM Setup 1 10 3 Information of BKSI 2011 1 16 3 1 Installation to BKSI 2010 1 16 4 Specifications 1 17 5 ISR ...

Page 4: ...ow to install the plug in board and connector panel to the System Interface Unit SIU 80 and function of switches and LEDs 3 Information of BKSI 2011 This section describes how to install the board to the BKSI 2010 4 Specifications This section describes the specifications of BKSI 2010 2011 5 ISR This section describes the overview of the ISR system Manual Structure Related manuals The following ma...

Page 5: ...wo channel signals for output through the SDDI When BKSI 2011 is mounted on BKSI 2010 the BKSI 2010 can process four channel signals for output One BKSI 2010 can control up to seven disk drives n BKSI 2010 does not receive Serial Digital Interface SDI signal BKSI 2011 Disk Controller Memory Board BKSI 2011 is for expanding the memory capacity of Disk Control Board BKSI 2010 By installing this BKSI...

Page 6: ...C EDITOR VS BUS RS 422A VS BUS I F RS 422A I F CPU SDDI SDDI SDDI I F AV BUFFER SDDI I F AV BUFFER SPC SCSI DD BKSI 2040 BKSI 2010 SMS Server Management System Software IDC Intelligent Device Controller SDDI Serial Digital Data Interface SPC SCSI Protocol Controller DD Disk Drive ...

Page 7: ...tch S3301 on a new board to the setting of the removed board Procedures 1 Turn off the power of the SIU 80 and remove the front panel and shield plate Refer to the Installation Manual supplied with SIU 80 2 Insert the board into a slot and then turn the board levers in the direction of the arrow 1 and connect the board securely to the connector of the SIU 80 s mother board 3 Install the shield pla...

Page 8: ... the connector panel is inserted into a slot the model label cannot be seen 4 Insert the connector panel to the matching slot and fix the panel by the two screws securing the rear blank panel Connector panel removal 1 Turn off the power of SIU 80 and unplug the appli ance from the outlet 2 Remove the two screws securing the connector panel and remove the connector panel m When removing the connect...

Page 9: ... Used for RS 422A remote control SONY DISK PROTOCOL signal is available for this terminal n This connector does not accept SONY VTR PROTOCOL signal 4 SCSI connector Differential P type 68 pin Connects to SCSI devices using a 68 pin cable corresponding to FAST WIDE 10 Mbyte s 16 bits differential type SCSI which is standard product n When connecting or disconnecting the SCSI cable turn off the powe...

Page 10: ...MOTE A D sub 9 pin Female D sub 9 pin Male 1 560 651 00 Connector REMOTE B 1 561 749 00 Shell RCC 5G 10G 30G Cable 1 1 751 019 81 5G 1 751 019 91 10G 1 751 020 21 30G SCSI Differential P Female Differential P Male Standard product Differential P Cable Standard product 1 Each length of cables is 5 m 10 m and 30 m 2 6 Signal Input Output Input and output signals of connector on the connector panel a...

Page 11: ...ND 56 BSY 57 ACK 58 RST 59 MSG 60 SEL 61 C D 62 REQ 63 I O 64 GROUND 65 DB 8 66 DB 9 67 DB 10 68 DB 11 SCSI SCSI Differential P type 68 pin Female External View Pin No Signal 1 DB 12 2 DB 13 3 DB 14 4 DB 15 5 DB P1 6 GROUND 7 DB 0 8 DB 1 9 DB 2 10 DB 3 11 DB 4 12 DB 5 13 DB 6 14 DB 7 15 DB P 16 DIFFSENS 17 TERMPWR 18 TERMPWR 19 RESERVED 20 ATN 21 GROUND 22 BSY 23 ACK 24 RST 25 MSG 26 SEL 27 C D 28...

Page 12: ...d rate for the ISR and maintenance mode by the ON and OFF combination n Do not set the switch to the ON and ON combina tion S3301 3 S3301 2 Baud Rate bps OFF OFF 19200 Factory setting OFF ON 38400 ON OFF 9600 S3301 4 BOOT ON OFF select Used when a program is downloaded or a system log data is uploaded If set to ON the program does not boot ON A program does not boot OFF A program boots Factory set...

Page 13: ...es TX1 and TX2 of SDDI output data and the type is selected automatically in the board D2203 A 10 PB indicator When DMA data for the playback process block is transferred on SCSI it lights in green S3001 A 10 RESET switch Push switch type Used for resetting CPU or starting the self diagnostics 2 7 2 IO 116 Board 1 RV100 D 12 Free run Frequency Adjustment volume For the details of the adjustment re...

Page 14: ...MAV S110 can be combined but Ciprico and MAV Series cannot be combined This mode is not used in STAS 10 Sony Transmission Automation System n After changing the connection of the arrays perform this setup Single File Mode This mode allows the arrays writable area connecting to the BKSI 2010 to operate as one file In this mode an available area of the arrays connecting to the BKSI 2010 are regarded...

Page 15: ...as follows Serial port COM1 Baud rate 19200 Parity None Flow Control None Stop bit length 1 bit Data bit length 8 bits For the display example in using a personal computer the following procedure differentiates between the characters displayed automatically on the screen and the characters to be entered as shown below Font and style of letters Display example Reference for Distinction Roman font S...

Page 16: ...isplay When using 2 arrays and Audio 4 channels SDC setup SDC Setup 1 Set Defaults to NOVRAM 2 Software Reset Multi File Format Mode 1 How many arrays to be connected 2 1 or 2 arrays 3 3 arrays Or enter 2 and hit the Enter key 4 4 arrays 5 5 arrays 6 6 arrays 7 7 arrays Enter number default is 2 2 How many audio channels Enter number default is 2 2 or 4 4 3 What is initial value of Start Time Code...

Page 17: ...ght Sony Corporation 1996 HELP CMD MAN VER README SETUP CMD SETUP DIAG CMD ADIAG MDIAG EDIC FILE CMD LS DEL LOG CMD CMDLOG SYSLOG SDC 5 Turn off the power of the SIU 80 6 Set S3301 1 to OFF 7 Remove the communication cable from CN1101 If any BKSI 2010 boards are installed in the SIU 80 8 Interchange the communication cable to CN1101 on another BKSI 2010 9 Perform steps 1 through 7 10 After the set...

Page 18: ... 2 arrays Ciprico and Audio 4 channels SDC setup 2 Or enter 1 and hit the Enter key SDC Setup 1 Set Defaults to NOVRAM n 2 Software Reset The storage time differs according to the Single File Format Mode for STAS 10 selected array type 1 Which type of array is connected STAS 10 Either system 525 and 625 1 Ciprico AUDIO 2CH AUDIO 4CH 2 MAV S100 1 Ciprico 3h30m 3h10m 3 MAV S110 2 MAV S100 3h00m 2h50...

Page 19: ...ght Sony Corporation 1996 HELP CMD MAN VER README SETUP CMD SETUP DIAG CMD ADIAG MDIAG EDIC FILE CMD LS DEL LOG CMD CMDLOG SYSLOG SDC 5 Turn off the power of the SIU 80 6 Set S3301 1 to OFF 7 Remove the communication cable from CN1101 If any BKSI 2010 boards are installed in the SIU 80 8 Interchange the communication cable to CN1101 on another BKSI 2010 9 Perform steps 1 through 7 10 After the set...

Page 20: ...nance Manual SCS 4 board 3 Information of BKSI 2011 3 1 Installation to BKSI 2010 1 Remove the three screws on the SCS 4 board shown in the figure 2 Temporarily secure the three brackets supplied with BKSI 2011 to the SCS 4 board by the screws removed in step 1 n Take care of the direction of bracket at installation 3 While inserting the brackets into the hole on the MY 72 board and matching the p...

Page 21: ...2 oz Power requirements 5 V dc 5 3 A 5 V dc 1 1 A supplied from SIU 80 Power consumption 32 W Input Output SDDI SDDI IN OUT connector BNC type 75 Ω 270 Mbps SCSI SCSI connector Differential P type 68 pin BKSI 2011 General Operating temperature 5 C to 40 C 41 F to 104 F Storage temperature 20 C to 60 C 4 F to 140 F Operating humidity 10 to 90 no condensation Dimensions 165 X 194 mm H W Mass 160 g P...

Page 22: ...is full SDDI CRC ERROR RX CRC error is detected in the SDDI input signal SCSI Block warning Message Description ILLEGAL PHYSICAL FORMAT Physical format of the disk is illegal SCSI BUS PARITY ERROR A parity error on SCSI bus is detected SCSI DATA ERROR A data error is occurred on the SCSI SCSI DEVICE HARDWARE ERROR A hardware trouble is detected in No of SCSI device SCSI DEVICE NOT RESPOND There is...

Page 23: ...DDI input signal error is detected VIDEO AUDIO TYPE ERROR Unsupported format type of audio video signal is input Reference Block warning Message Description REFERENCE NOT EXIST Reference signal is not entered REFERENCE UNLOCK Reference signal does not lock Process Block warning Message Description COMMAND BUFFER FULL A command buffer is full FUNCTION ABORT An operation is aborted TEST MODE IN PROG...

Page 24: ...ified duration SEND Sending the file RECEIVE Receiving the file READ Reading a non AV data WRITE Writing a non AV data DELETE Deleting the file COPY Copying the file SHUTTLE Playing back an AV data in shuttle mode JOG Playing back an AV data in jog mode VAR Playing back an AV data in variable mode PROGRAM SPEED PLAY Playing back an AV data in program speed mode STEP Playing back an AV data in step...

Page 25: ... mounted on the board Board name ROM name version board address and blank ROM name 5 2 ISR Use Environment The ISR function is controlled by Sony application program software For the program software use installation and operation of a personal computer in which this program software can be used consult with your local sony s sale service office The preparation below is required when managing the ...

Page 26: ......

Page 27: ...des acquéreurs de l équipement décrit dans ce manuel Sony Corporation interdit formellement la copie de quelque partie que ce soit de ce manuel ou son emploi pour tout autre but que des opérations ou entretiens de l équipement à moins d une permission écrite de Sony Corporation Das in dieser Anleitung enthaltene Material besteht aus Informationen die Eigentum der Sony Corporation sind und ausschli...

Page 28: ...Printed in Japan Sony Corporation 1997 3 16 Broadcast Products Company 1996 Published by Broadcast Products Company BKSI 2010 SY BKSI 2011 SY J E 3 190 290 03 ...

Reviews: