6. ATA Command Specification
Sleep
SONY AIT-2 Turbo drive SDX-560V series Ver.1.0
6-26
6.11. Sleep (E6h)
This is implemented for compatibility issues. It is treated as an idle command.
Inputs
Register
7 6 5 4 3 2 1 0
Features
na
Sector Count
na
Sector Number
na
Cylinder Low
na
Cylinder High
na
Device/Head
1 na 1 DEV
na na na na
Command
E6h
Device/Head register -
DEV indicates the selected device.
Normal outputs
Register
7 6 5 4 3 2 1 0
Error
na
Sector Count
na
Sector Number
na
Cylinder Low
na
Cylinder High
na
Device/Head
1 na 1 DEV
na
Status
BSY DRDY DF DSC DRQ na na CHK
Device/Head register -
DEV indicates the selected device.
Status register -
BSY is cleared to zero when the command is completed.
DRDY is set to one.
DF is cleared to zero.
DSC is set to one.
DRQ is cleared to zero.
CHK is cleared to zero.
Error outputs
Register
7 6 5 4 3 2 1 0
Error
na ABRT
na
Sector Count
na
Sector Number
na
Cylinder Low
na
Cylinder High
na
Device/Head
1 na 1 DEV
na
Status
BSY DRDY DF DSC DRQ na na CHK
Error register -
ABRT is set to one if the Sony ATAPI Drive is not able to complete the action requested by the
command.
Device/Head register -
DEV indicates the selected device.