5-4.
SD Signal System Adjustment
5-4-1.
VBS Output Level Adjustment
Measuring equipment
SD waveform monitor
Preparation
Extend the EN-159A/159B board using an extended board.
Adjustment Procedure
Test Point: VBS OUT connector/ VDA-64A board
Adjusting Point: RV303 (F-3)/EN-159A/159B board
Specification:
A = 140 ±1 IRE (75 Ω termination)
B = 1000 ±7 mVp-p (75 Ω termination)
EN-159A/159B board (Side A)
A B C D E F G H J
1
2
3
4
5
RV303
B
A
NTSC
PAL
5-4-2.
PIX Output Level Adjustment
Measuring equipment
SD waveform monitor
HDCU2500
5-11