Trouble Shooting Guide
,
Mechanical
4/000 21-1/FEA 209 544/123 A
Company Internal
©
Sony Ericsson Mobile Communications AB
9(30)
Problem Area
Items to Inspect
Repair Action
Inspection Reference
Inspect the two connections where
the camera flex assembly connects
to the circuit board
•
If either connection is improperly
connected - Reestablish proper
connection
•
If one or both of the connections is
dirty or oxidized – Clean both halves
of the connection(s)
•
If any portion on the camera assembly
flex film is damaged – replace the
camera flex assembly
•
If either of the camera flex assembly
connections on the circuit board is
damaged – Send to a repair location
allowed to perform electrical repairs
on this product
If the issue has not been resolved
!
•
Replace the camera assembly, if it
has not been replaced
If the issue is still not resolved
!
•
Send to a repair location allowed to
perform electrical repairs on this
product