Fig. 3: Filter settings 

 

Check whether the correct COM-Port has been selected.  

 

Select the “Without filter” setting as standard for the read-
out head. 

Depending on the read-out  head type the signal must be 
filtered for successful communication.   

 

Close the window and attempt communication with the 
new setting again. 

If detection fails: 

 

Set the filter to “Echo”:  

Attempt communication again with the new setting. 

If detection fails: 

 

Set the filter to “Noise”.  

Attempt communication again with the new setting 

If detection fails, use a different read-out head or PC. 

5.1.6.1  Known configuration of certain read-out heads 

The read-out heads listed below function with the indicated filter settings with Prog470/Prog479 
software impeccably: 
 

Read-out head 

Filter setting 

P+E Technology: “K1-98” or “K1-06”  

Without filter 

P+E Technology: “K01-USB” 

Without filter 

Siemens  

Echo 

5.1.6.2  Standard communication parameters 

The transmission speed of the communication interfaces is defined by the following parameters: 
 

Interface 

Speed [Baud] 

Parity 

M-Bus (above 

RS232) 

9600 

straight 

Optical 

9600  

straight 

5.1.6.3  Reading the configuration of the Superstatic 470/479 computing unit 

When configuration of the communication interface has been terminated, actuate the “Detect 
device” key in order to read the configuration of the computing unit 470/479: 
 

 

Fig 4: Detect device 

5.1.7  “Modules” tab 

As soon as the computing unit has been read by the software Prog470/Prog479, select the 
“Modules” tab and detect the SPF module. The configuration parameters are displayed in the 
“Modules” tab of the Prog470/Prog479 software. 
 

0470P004 Manual Superstatic 470 SPF 02-03-2015

 

 

15 

Summary of Contents for Superstatic 470 SPF

Page 1: ...Rev 02 03 2015 0470P004 Manual Superstatic 470 SPF 02 03 2015 Sontex SA DMS Metering Solutions X Cel House Chrysalis Way Langley Bridge Eastwood NG16 3RY Tel 01773 534555 Fax 01773 534666 Email sales...

Page 2: ...ith energy 10 01 2014 10 01 14 SV Images of modification 02 12 2014 02 12 14 SV Update 19 01 2015 19 01 15 SV Update display sequences 17 02 2015 17 02 15 SV Update layout 18 02 2015 18 02 15 SV Updat...

Page 3: ...tion board of the computing unit 8 3 2 2 Heat pump Module 8 3 3 Error messages 9 3 3 1 List of error messages 9 4 Use of the Superstatic 470 479 10 4 1 Communication protocol 10 4 1 1 Prog470 Prog479...

Page 4: ...dified in any way whatever Notes on installation of the meter Comply with conditions of use as defined in Directive 2004 22 EC MID and correct installation positions For further information about the...

Page 5: ...mp module By means of the Prog470 Prog479 software the configuration of the Superstatic 470 479 and the parameterisation of the inputs used for calculation of the performance factors can be detected a...

Page 6: ...the previous period is stored and can be displayed The value SPF2 shows the performance factor of the heat pump since its initial commissioning The SPF2 is never reset The SPF3 value shows the perfor...

Page 7: ...e time of dispatch from the factory To maintain that condition and ensure safe operation of the appliance the user must comply with the instructions set out in this document When opening covers or rem...

Page 8: ...ditional meter 2 16 Open Collector Output 1 17 Open Collector Outputs 1 2 18 Open Collector Output 2 24 M Bus module fitted ex works connect nothing on top 25 M Bus module fitted ex works connect noth...

Page 9: ...er part terminal strip Err128 Internal electronic fault back to the manufacturer Err256 Voltage failure power supply module Err512 Defective module plug location 1 Err1024 Defective module plug locati...

Page 10: ...of the Superstatic 470 479 computing unit can be transferred directly to the Prog470 Prog479 software on a PC or vice versa 4 2 Display LCD operating concept The navigation key enables the different...

Page 11: ...shown in the first position on the display as long as it is present When the fault disappears the fault report is deleted from the display 4 2 2 Display sequence The following display sequences can be...

Page 12: ...31 Configuration of the digital inputs Digital input Pulse factor Unit Tipe 00000063 a1 a1 W h 1 00000063 a2 a2 W h 1 00000063 a3 1 000 a3 Mn 00000000 a4 1 a4 00000000 a5 a5 W h 1 00000000 a6 a6 off a...

Page 13: ...ttp www sontex ch downloads_e html The data file must be downloaded into a folder on your PC e g in C Sontex Prog470 Vx xxx Make sure that none of the data files contained in this folder are write pro...

Page 14: ...serial cable RS232 via the M Bus protocol The M Bus protocol is used on the basis of European standard EN13757 3 for communication between the software and the computing unit Select the communication...

Page 15: ...impeccably Read out head Filter setting P E Technology K1 98 or K1 06 Without filter P E Technology K01 USB Without filter Siemens Echo 5 1 6 2 Standard communication parameters The transmission spee...

Page 16: ...communication interface Digital inputs M Bus communication interface Standard M Bus communication interface configuration Transmission speed Primary address Possibility of connecting a modem Parameter...

Page 17: ...ing Amount counting Slow Binary counting pulse counting The work unit must be the Wh The pulse factor Ax factor must be defined according to the unit Wh The initial value Ax value corresponds to the s...

Page 18: ...se factor Ax factor must be defined according to the unit Wh Example A pump of 400W switched on during 1 hour consumes an electrical energy of 400Wh The factor Ax factor will be configured with 400 Wh...

Page 19: ...Notes 0470P004 Manual Superstatic 470 SPF 02 03 2015 19...

Page 20: ...port please contact the local Sontex representations or Sontex SA directly Sontex hotline sontex sontex ch 41 32 488 30 04 0470P004 Manual Superstatic 470 SPF 02 03 2015 Sontex SA 2013 0470P004 Manual...

Reviews: