Fig. 3: Filter settings
Check whether the correct COM-Port has been selected.
Select the “Without filter” setting as standard for the read-
out head.
Depending on the read-out head type the signal must be
filtered for successful communication.
Close the window and attempt communication with the
new setting again.
If detection fails:
Set the filter to “Echo”:
Attempt communication again with the new setting.
If detection fails:
Set the filter to “Noise”.
Attempt communication again with the new setting
If detection fails, use a different read-out head or PC.
5.1.6.1 Known configuration of certain read-out heads
The read-out heads listed below function with the indicated filter settings with Prog470/Prog479
software impeccably:
Read-out head
Filter setting
P+E Technology: “K1-98” or “K1-06”
Without filter
P+E Technology: “K01-USB”
Without filter
Siemens
Echo
5.1.6.2 Standard communication parameters
The transmission speed of the communication interfaces is defined by the following parameters:
Interface
Speed [Baud]
Parity
M-Bus (above
RS232)
9600
straight
Optical
9600
straight
5.1.6.3 Reading the configuration of the Superstatic 470/479 computing unit
When configuration of the communication interface has been terminated, actuate the “Detect
device” key in order to read the configuration of the computing unit 470/479:
Fig 4: Detect device
5.1.7 “Modules” tab
As soon as the computing unit has been read by the software Prog470/Prog479, select the
“Modules” tab and detect the SPF module. The configuration parameters are displayed in the
“Modules” tab of the Prog470/Prog479 software.