5

Instruction for use | Superaqua 1

2. Security

   

 

 

 

Improper installation, pressure tests, modifications or incorrect

 

 

 

operation can cause personal injury and damage to property. 

 

 

 

Pressure surges in the pipeline can damage the meter! 

 

 

 

Existing air pockets falsify the measuring result. 

 

If the seal is damaged or removed, the water meter is no longer approved for legal metering  

     legal measurement. 

 

Before installation, check water meter for transport damage.

 

 

Do not drop, never hold on to the protective cover or the counter.

 

 

If the water meter has been dropped, it must not be installed again.

 

 

Only use suitable lubricants for EPDM seals. 

 

Water meters may only be installed after a pressure test. 

 

Water meters may only be installed in pipelines that have already been leak-tested, rinsed and 

 

     must be well vented before commissioning.  

 

Ensure that the water meter is always fully filled with water.

 

2.1 Personnel qualification

The water meter may only be installed or replaced by qualified personnel for sanitary, heating and 

air-conditioning technology.

2.2 Intended use 

 

 

 

Water meters are used for recording the consumption of drinking water,  

 

 

 

depending on the design for cold or hot water. Other applications that  

 

 

 

differ from these specifications must be approved in writing by Sontex  

   SA.

 

 

 

 

Water meters are exclusively intended for the above-mentioned       

 

                              purpose.  Any other use or modification of the water meters beyond this 

 

 

 

purpose is considered improper and is not permitted. 

   

 

 

 

Warranty only after proven compliance with these regulations and the  

   applicable 

technical 

rules.

 

 

For the period of use, observe all valid national legal regulations 

 

     in particular the calibration regulations. 

 

During installation, observe all specifications according to DIN EN 806 and DIN 1988, in 

     particular hygiene regulations and ambient temperatures. 

 

Observe the nominal operating conditions according to the type examination certificate and the  

     information on the devices. 

 

Keep these instructions with the measuring device

 

Summary of Contents for SQ1M

Page 1: ...Instruction for Use Superaqua 1...

Page 2: ...ce dimensions Multi jet measuring capsule 9 5 1 Mounting of measuring capsule 9 6 Device labelling 10 6 1 Display 11 6 2 Delivery mode 11 6 3 Switch to operating mode radio activation 11 6 4 Radio act...

Page 3: ...for Superaqua 1 will be explained as a note in the current man ual s different sections 1 2 Target groups This documentation is intended for the system operator and the installer 1 3 Ablage des Dokume...

Page 4: ...n observance of which may result in damage to property Reference Information that is important for a specific topic or goal but not relevant to security Documentation Reference to documentation Help H...

Page 5: ...nel qualification The water meter may only be installed or replaced by qualified personnel for sanitary heating and air conditioning technology 2 2 Intended use Water meters are used for recording the...

Page 6: ...6 Instruction for use Superaqua 1 3 Scope of delivery Transport Storage Cleaning Tools MB2 Single jet Measuring capsule...

Page 7: ...7 Instruction for use Superaqua 1 4 Dimension Single jet 4 1 Mounting instruction for single jet water meter...

Page 8: ...8 Instruction for use Superaqua 1...

Page 9: ...9 Instruction for use Superaqua 1 5 Dimension Multi jet measuring capsule 5 1 Mounting instruction for multi jet measuring capsule D1 75 mm D2 70 mm H von ca 35 bis 62 mm...

Page 10: ...MID Homologation N Pressure range Part N Radio communication Sontex 433 MHz wM Bus 868 MHz LoRaWAN 868 MHz CE marking and test laboratory N MID Measuring range class Temperarure T30 or T90 Flow rate...

Page 11: ...io Opening a water tap for a few seconds triggers the switchover of the water meter to the operating mode The device display changes and only then the radio is also started A standard minimum volume o...

Page 12: ...6 6 Device display loop Display Display time Example 10 s Consumption 36 214 m3 Current flow rate 15 l h 3 s optional Set day value 175 m3 Check number c85 Set day 01 01 Min 1 s can be exten ded Firm...

Page 13: ...op of the battery Attention The device must be replaced Overview of event and error messages For various analyses it is very helpful to examine the chronological course of events To make this possible...

Page 14: ...Installer read and change settings Verifier read and change metrological parameters The installer password is 0x1234 The installer password can be changed or disabled 7 1 Volume stored data The curre...

Page 15: ...dio telegram C1 or T1 transmission power 14 dBm 25 mW LoRaWAN Frequency 868 MHz bidirectional transmission power 14 dBm 25 mW 9 Technical data Dimension Single Jet lenght L height H Multi Jets measuri...

Page 16: ...tore lithium batteries protected from moisture do not heat above 100 C or throw into fire Do not short circuit open damage or charge lithium batteries Always keep lithium batteries out of the reach of...

Page 17: ...17 Instruction for use Superaqua 1...

Page 18: ...32 488 30 00 sontex sontex ch www sontex ch 21 06 Technical support For technical support contact your local Sontex agent or Sontex SA directly Hotline Sontex support sontex ch 41 32 488 30 04 Techni...

Reviews: