Instruction for use | Superaqua 1
8. Standard radio settings
Term
OMS settings
Encryption
Mode 5
AES128 key
Individual
wM-Bus
OMS short telegram
wM-Bus transmission mode
T1
Radio calendar
Mo-Su, 0.00 to 23.59, Jan-Dec.
Transmission interval
2 Min.
End of device life reached (D/Ö)
No
Display flow rate
Yes
Leackage
Yes
8.1 Radio settings configuration
To configure the radio settings you can use the parameterization software Superprog. You will
find instructions for setting the radio parameters in the help menu of the Superprog software.
8.2 Radio connections
Sontex Radio
Frequency: 433 MHz, bidirectional, transmission power: 10 dBm (10 mW)
wM-Bus OMS
Frequency: 868 MHz, unidirectional, Mode 5 or 7, Radio telegram C1 or T1, transmission power: 14 dBm (25 mW)
LoRaWAN
Frequency: 868 MHz, bidirectional, transmission power: 14 dBm (25 mW)
9. Technical data
Dimension
Single Jet
lenght L
height H
Multi-Jets measuring capsule
Diameter D1
Diameter D2
height H
80, 110, 115, 130, or 165 mm
approx. 52 mm
75 mm
70 mm
from 35 to 62 mm
Measurement
Approved temperature Cold water
Approved temperature Warm water
Volume measurement cycle at nominal flow
+0.1°C ... +50°C
+0.1°C ... +90°C
0.5 seconds
Digital Register
Environment class
Mechanics
Electronics
Battery protection class
Protection class
Operating temperature
Storage and transport temperature
B
M1
E1
III
IP68 (4 weeks under 1m water)
5...55°C
-10...60°C (dry environment)
Display & Display Units
LCD
Volume resolution (display)
Volume
Flow
Flow symbol (flashes when there is flow)
Battery status
Radio
8 digits
0.001
m
3
l/h
Power Supply
Lithium Battery (< 1 g) 3 VDC
up to 15 years