background image

SONOFLOW

®

 IL.52/3 V2.0 

Technical Data Sheet

 

Ultrasonic Flow Sensor 

 

 

 

 

Revision: 1.3; Date: 2020-05-18

 

Technical drawings 

        

 

Figure 1: Dimensions SONOFLOW

®

 IL.52/3 V2.0 – Side view  

      

 

Figure 2: Rear side with drill holes for mounting  

 

 

4x threaded holes M5/ depth: 10 

Drawings are not to scale. Dimensions in mm, unless otherwise specified. Information is subject to change without notice.  

 

 

 

HEADQUARTERS GERMANY

 

 

SONOTEC GmbH 

Nauendorfer Str. 2 

06112 Halle (Saale) 

Germany 

 

 

 

 

 

Tel.: +49 (0)345 / 133 17- 0 

[email protected] 

www.sonotec.eu 

 

AMERICAS

 

 

SONOTEC US Inc. 

190 Blydenburgh Rd 

Suite 8, 2

nd

 Floor 

Islandia, New York 11749, USA 

 

 

 

 

Phone: +1 631 / 415 4758 

[email protected] 

www.sonotecusa.com 

 

 

Summary of Contents for 200 08 0001

Page 1: ...Ultrasonic Flow Sensor SONOFLOW IL 52 V2 0 User Documentation Including Technical Data Sheet Operating Manual Certificates...

Page 2: ...This page has been deliberately left empty...

Page 3: ...in areas with rigorous hygiene requirements the sensor is suitable for circulation cleaning and steam sterilization General data SONOFLOW IL 52 3 V2 0 Ultrasonic Flow Sensor for Liquids Order No IL 5...

Page 4: ...on FFKM Operating voltage 12 30 VDC ripple max 10 protection against reverse polarity external fuse if required min 200 mA Current consumption Maximum 50 mA with open current frequency and switching o...

Page 5: ...e interface is not used it does not necessarily has to be connected the two pins A and B can remain open RS485 Bus operation The sensor supports bus operation with max 12 subscribers The default addre...

Page 6: ...temperature 0 70 C Storage temperature 20 70 C Directives and standards EMC directive 2014 30 EU RoHS 2011 65 EU exception III 7cI IV 15 Acoustic emission IEC 61157 Maintenance Maintenance free Scope...

Page 7: ...le connector at the sensor Female connector at the cable M12 connecting cable Pin Color Connection Assignment 1 White Ground 2 Brown Operating voltage 12 30 VDC 3 Green Current output 0 4 20 mA 4 Yell...

Page 8: ...ded holes M5 depth 10 Drawings are not to scale Dimensions in mm unless otherwise specified Information is subject to change without notice HEADQUARTERS GERMANY SONOTEC GmbH Nauendorfer Str 2 06112 Ha...

Page 9: ...Ultrasonic Flow Sensor Type SONOFLOW IL 52 V2 0 Operating Manual...

Page 10: ...SONOTEC Ultraschallsensorik Halle GmbH All rights reserved Revision 1 0 Date 2018 10 26 Information is subject to change without notice...

Page 11: ...ing 10 3 4 Requirements for Liquid 10 3 5 Parameterization calibration and readout of measuring values Accessories 10 4 Installation and commissioning 11 4 1 Attaching the Sensor SONOFLOW IL 52 V2 0 1...

Page 12: ...SONOFLOW IL 52 V2 0 Operating Manual 4 Revision 1 0 Date 2018 10 26 This page has been deliberately left empty...

Page 13: ...all the instructions to ensure safe operation of the SONOFLOW IL 52 V2 0 1 2 Symbols used Hazards or special information is indicated in the following ways Warns of imminent threat of danger with very...

Page 14: ...SONOFLOW IL 52 V2 0 Operating Manual 6 Revision 1 0 Date 2018 10 26 This page has been deliberately left empty...

Page 15: ...chnical Data Sheet Make sure to read all safety regulations NEVER CHANGE SETTINGS of the sensor before you have saved all parameters with the help of SONOFLOW Monitor Ignoring the safety instructions...

Page 16: ...temperatures and voltage range must be met unconditionally Values are not allowed to exceed or to fall below the specified limits not even temporarily The sensor may only be exposed to a minimal risk...

Page 17: ...including to third parties caused by improper handling of the sensors 3 2 Construction The SONOFLOW IL 52 V2 0 consists of two ultrasonic transducers appropriate control electronics and evaluation el...

Page 18: ...le Frequency output for flow rate 0 to 20 kHz 5 V digital RS485 interface bus capable Switching output configurable as PNP NPN Push Pull 0 to 30 V Digital input MODBus on request Please find the descr...

Page 19: ...rations can affect sensor functions Ensure that the mounting or the tubes lines do not transmit vibrations to the sensor Recommended is an installation position with a flow direction against the force...

Page 20: ...mA Range 4 20 mA 0 20 mA Limit 20 mA 20 mA Flow min 0 ml min 4 mA 0 3 000 ml min Flow max 3 000 ml min 20 mA 0 3 000 ml min Measuring Error 2 mA 0 22 mA Device Fault 0 mA 0 22 mA Table 3 Default setti...

Page 21: ...ulse volume Pulse volume in ml Threshold Flow On 1500 ml min 0 3 000 ml min Threshold Flow Off 1200 ml min 0 3 000 ml min Totalized volume Enable volume calculation Enable negative volume Table 5 Defa...

Page 22: ...gs 14 Revision 1 0 Date 2018 10 26 5 5 Digital input Parameter Default setting Further options via SONOFLOW Monitor Configuration Flow Zero Adjust OFF Reset Volume Restart Option to Zero adjust Deacti...

Page 23: ...send via the configured outputs If there is visible damage take the sensor out of operation immediately 6 2 Cleaning and Disinfection Incorrect cleaning of the sensors SONOFLOW IL 52 V2 0 and its com...

Page 24: ...sensor has self test routines and sets defined output signals if an error is detected The error output can be customized Description Remedy Measuring Error e g gas in the sensor Try to remove the gas...

Page 25: ...range a separate disposal for electronic equipment It has to be handled according to specific processes e g concerning the batteries or circuit boards to ensure a safe environmentally friendly recycli...

Page 26: ...UFACTURER SONOTEC Ultraschallsensorik Halle GmbH Nauendorfer Str 2 06112 Halle Saale Germany Tel 49 0 345 133 17 0 sonotec sonotec de www sonotec de USA CONTACT DETAILS SONOTEC US Inc 190 Blydenburgh...

Page 27: ......

Page 28: ......

Page 29: ...This page has been deliberately left empty...

Page 30: ...om SONOTEC GmbH All rights reserved The content of this manual is the property of SONOTEC Ultraschallsensorik Halle GmbH and is protected by copyright Duplication and distribution in any form particul...

Reviews: