background image

 

1

Contents

Introduction

 

.............................................................1

Kit

 

contents

 

..............................................................1

About

 

the

 

remote

 

control

 

......................................2

Connecting

 

the

 

remote

 

control

 

.............................4

Controlling

 

the

 

ultrasound

 

system

 

......................5

Using

 

multiple

 

ultrasound

 

systems

 

.....................8

Using

 

multiple

 

SonoRemote

 

controls

 

..................8

Working

 

in

 

a

 

sterile

 

environment

 

........................8

Safety

 

........................................................................9

Maintenance

 

..........................................................11

Specifications

 

.........................................................12

Introduction

The

 

SonoRemote

 

Control

 

User

 

Guide

 

explains

 

how

 

to

 

use

 

the

 

SonoRemote™

 

control

 

with

 

the

 

M

Turbo

®

 

ultrasound

 

system

 

or

 

S Series™

 

ultrasound

 

system.

For

 

more

 

information

 

on

 

the

 

ultrasound

 

system,

 

see

 

the

 

ultrasound

 

system

 

user

 

guide.

Conventions

The

 

user

 

guide

 

follows

 

these

 

conventions:

• A

 

WARNING

 

describes

 

precautions

 

necessary

 

to

 

prevent

 

injury

 

or

 

loss

 

of

 

life.

• A

 

Caution

 

describes

 

precautions

 

necessary

 

to

 

protect

 

the

 

products.

• Numbered

 

steps

 

must

 

be

 

performed

 

in

 

order.

• Single

step

 

procedures

 

begin

 

with

 

™

.

• Items

 

in

 

bulleted

 

lists

 

do

 

not

 

require

 

a

 

sequence.

See

 

also

 

“Labeling

 

symbols”

 

on

 

page 12.

Customer comments

Questions

 

and

 

comments

 

are

 

encouraged.

 

SonoSite

 

is

 

interested

 

in

 

your

 

feedback

 

regarding

 

the

 

system

 

and

 

the

 

user

 

guide.

 

Please

 

call

 

SonoSite

 

at

 

888

482

9449

 

in

 

the

 

US.

 

Outside

 

the

 

US,

 

call

 

the

 

nearest

 

SonoSite

 

representative.

 

You

 

can

 

also

 

e

mail

 

SonoSite

 

at

 

[email protected].

 

For

 

technical

 

support,

 

see

 

“Technical

 

support”

 

on

 

page 11.

Kit contents

The

 

SonoRemote

 

control

 

kit

 

contains

 

the

 

following

 

items:

• remote

 

control

• USB

 

cable

• Bluetooth

®

 

USB

 

adapter

• Microphone

• Sterile

 

sheath

 

for

 

remote

 

control

 

(5)

• MAC

 

address

 

labels

 

(14)

To apply the MAC address label

The

 

remote

 

control’s

 

Media

 

Access

 

Control

 

(MAC)

 

address

 

lets

 

you

 

distinguish

 

your

 

remote

 

control

 

from

 

other

 

Bluetooth

 

devices

 

and

 

make

 

sure

 

that

 

the

 

correct

 

device

 

is

 

connected.

 

To

 

find

 

the

 

MAC

 

address,

 

you

 

connect

 

by

 

Bluetooth

 

technology.

 

1

Find

 

the

 

MAC

 

address:

 

Connect

 

by

 

Bluetooth

 

technology.

 

See

 

“To

 

connect

 

by

 

Bluetooth

 

technology”

 

on

 

page 5.

The

 

MAC

 

address,

 

BlueHID ##:##

 

(where

 

##:##

 

are

 

four

 

unique

 

numbers),

 

appears

 

in

 

the

 

Bluetooth

 

Devices

 

list.

2

Remove

 

a

 

label

 

from

 

its

 

protective

 

backing.

3

Adhere

 

the

 

label

 

to

 

the

 

back

 

of

 

the

 

remote

 

control,

 

in

 

the

 

rectangular

 

area

 

on

 

the

 

bottom.

4

Using

 

a

 

permanent

 

marker,

 

write

 

the

 

MAC

 

address

 

on

 

the

 

label.

 

(You

 

can

 

also

 

write

 

Summary of Contents for SonoRemote Control

Page 1: ...SonoRemote Control User Guide...

Page 2: ......

Page 3: ...SonoRemote Control User Guide...

Page 4: ...135961 6203498 6364839 6371918 6383139 6416475 6447451 6471651 6569101 6648826 6575908 6604630 6817982 6835177 6962566 7169108 7449640 D456509 D461895 D509900 D538432 D544962 D558351 D559390 and by th...

Page 5: ...is interested in your feedback regarding the system and the user guide Please call SonoSite at 888 482 9449 in the US Outside the US call the nearest SonoSite representative You can also e mail SonoSi...

Page 6: ...control lets you control the ultrasound system from up to 30 feet away Using six buttons or voice commands you can perform the following tasks Freeze or unfreeze an image Save an image Adjust the gai...

Page 7: ...ing the battery Before using the remote control make sure that the battery is charged You can charge one remote control while using another that is connected by Bluetooth technology The battery is nea...

Page 8: ...eeps and the Bluetooth indicator blinks quickly To connect by Bluetooth technology 1 Turn on the system 2 Insert the Bluetooth USB adapter into a USB port on the system 3 Display the USB Devices setup...

Page 9: ...s to Connected To disconnect the remote control 1 On the ultrasound system s USB Devices setup page select Bluetooth See To display the USB Devices setup page on page 1 2 Select the remote control Blu...

Page 10: ...If you hear three warning beeps ignore them c Attach the microphone to your clothing near your mouth d If you wear a mask during ultrasound procedures put on a mask 2 Start training mode Press for mo...

Page 11: ...in the remote control or use the buttons See also Troubleshooting on page 11 Using custom phrases When training the remote control you can use custom phrases With some voices the remote control respon...

Page 12: ...consider including the following tasks when setting up If you use voice commands put on the microphone before putting on the smock Encase the remote control in the recommended sterile sheath Or if you...

Page 13: ...ance of other electrical equipment in the vicinity Operation conditions Operation is subject to the following two conditions This device may not cause harmful interference This device must accept any...

Page 14: ...duce potential for harmful interference to co channel Mobile Satellite systems High power radars are allocated as primary users meaning they have priority of 5250 5350 MHz and 5650 5850 MHz and these...

Page 15: ...tem behaves unexpectedly for example the image unexpectedly freezes or changes make sure that it is not connected to another remote control The ultrasound system can respond from up to 30 feet away to...

Page 16: ...ring the remote control is included Contact CIVCO for additional sheaths Labeling symbols The following labeling symbols are on the product and packaging Dimensions Width 61 1 mm Height 111 1 mm Depth...

Page 17: ......

Page 18: ...P11771 01 P11771 01...

Reviews: