SonoSite SonoRemote Control User Manual Download Page 11

 

7

Use

 

the

 

same

 

volume

 

and

 

clarity

 

that

 

you

 

use

 

during

 

ultrasound

 

procedures.

If

 

the

 

remote

 

control

 

beeps

 

only

 

once

 

when

 

expected

 

to

 

beep

 

twice,

 

repeat

 

the

 

phrase

 

until

 

it

 

beeps

 

twice.

The

 

long

 

beep

 

indicates

 

that

 

the

 

training

 

is

 

complete.

4

Test

 

the

 

voice

 

commands.

To test the voice commands

1

Set

 

up

 

the

 

equipment

 

and

 

environment:

a

Turn

 

on

 

the

 

ultrasound

 

system

 

and

 

the

 

remote

 

control.

 

(See

 

“Turning

 

on

 

power

 

and

 

charging

 

the

 

battery”

 

on

 

page 3.)

b

Connect

 

the

 

following:

• The

 

microphone

 

to

 

the

 

remote

 

control:

 

Insert

 

the

 

microphone

 

connector

 

into

 

the

 

microphone

 

port.

• The

 

remote

 

control

 

to

 

the

 

ultrasound

 

system

 

(See

 

“Connecting

 

the

 

remote

 

control”

 

on

 

page 4.)

c

Attach

 

the

 

microphone

 

to

 

your

 

clothing,

 

near

 

your

 

mouth.

d

If

 

you

 

wear

 

a

 

mask

 

during

 

ultrasound

 

procedures,

 

put

 

on

 

a

 

mask.

e

If

 

you

 

plan

 

to

 

wear

 

the

 

microphone

 

under

 

a

 

smock

 

in

 

ultrasound

 

procedures,

 

put

 

the

 

microphone

 

under

 

a

 

smock.

2

Speak

 

each

 

phrase

 

that

 

you

 

used

 

to

 

train

 

the

 

remote

 

control,

 

and

 

make

 

sure

 

that

 

the

 

ultrasound

 

system

 

responds

 

as

 

expected.

If

 

the

 

ultrasound

 

system

 

does

 

not

 

respond

 

as

 

expected,

 

retrain

 

the

 

remote

 

control,

 

or

 

use

 

the

 

buttons.

 

See

 

also

 

“Troubleshooting”

 

on

 

page 11.

Using custom phrases

When

 

training

 

the

 

remote

 

control,

 

you

 

can

 

use

 

custom

 

phrases.

 

With

 

some

 

voices,

 

the

 

remote

 

control

 

responds

 

to

 

custom

 

phrases

 

better

 

than

 

to

 

the

 

default

 

phrases.

 

Make

 

sure

 

to

 

say

 

the

 

custom

 

phrases

 

in

 

order.

 

Phrases

 

do

 

the

 

following:

Phrase 1

 

Decreases

 

depth

Phrase 2

 

Decreases

 

gain

Phrase 3

 

Increases

 

gain

 

(live

 

image),

 

reviews

 

the

 

cine

 

buffer

 

(frozen

 

image)

Phrase 4

 

Increases

 

depth

 

(live

 

image),

reviews

 

the

 

cine

 

buffer

 

(frozen

 

image)

Phrase 5

 

Freezes

 

(or

 

unfreezes)

 

the

 

image

Phrase 6

 

Saves

 

the

 

image

Choose

 

phrases

 

that

 

are

 

easy

 

to

 

remember,

 

sound

 

different

 

from

 

each

 

other,

 

and

 

sound

 

different

 

from

 

other

 

phrases

 

used

 

during

 

ultrasound

 

procedures.

 

Longer

 

phrases

 

typically

 

work

 

better

 

than

 

shorter

 

phrases

 

because

 

they

 

contain

 

more

 

sound

 

information.

 

Also,

 

try

 

to

 

vary

 

the

 

length

 

of

 

phrases.

Reviewing the cine buffer

When

 

the

 

image

 

is

 

frozen,

 

you

 

can

 

review

 

the

 

cine

 

buffer

 

by

 

using

 

the

 

same

 

buttons

 

and

 

voice

 

commands

 

that

 

adjust

 

the

 

gain

 

on

 

a

 

live

 

image.

Say:

 

Wait for:

Repeat: Wait for:

1

Depth
up

beep

Depth
up

2 beeps

2

Gain 
down

beep

Gain
down

2 beeps

3

Gain
up

beep

Gain
up

2 beeps

4

Depth 
down

beep

Depth
down

2 beeps

5

Freeze

beep

Freeze

2 beeps

6

Save

beep

Save

long beep

Summary of Contents for SonoRemote Control

Page 1: ...SonoRemote Control User Guide...

Page 2: ......

Page 3: ...SonoRemote Control User Guide...

Page 4: ...135961 6203498 6364839 6371918 6383139 6416475 6447451 6471651 6569101 6648826 6575908 6604630 6817982 6835177 6962566 7169108 7449640 D456509 D461895 D509900 D538432 D544962 D558351 D559390 and by th...

Page 5: ...is interested in your feedback regarding the system and the user guide Please call SonoSite at 888 482 9449 in the US Outside the US call the nearest SonoSite representative You can also e mail SonoSi...

Page 6: ...control lets you control the ultrasound system from up to 30 feet away Using six buttons or voice commands you can perform the following tasks Freeze or unfreeze an image Save an image Adjust the gai...

Page 7: ...ing the battery Before using the remote control make sure that the battery is charged You can charge one remote control while using another that is connected by Bluetooth technology The battery is nea...

Page 8: ...eeps and the Bluetooth indicator blinks quickly To connect by Bluetooth technology 1 Turn on the system 2 Insert the Bluetooth USB adapter into a USB port on the system 3 Display the USB Devices setup...

Page 9: ...s to Connected To disconnect the remote control 1 On the ultrasound system s USB Devices setup page select Bluetooth See To display the USB Devices setup page on page 1 2 Select the remote control Blu...

Page 10: ...If you hear three warning beeps ignore them c Attach the microphone to your clothing near your mouth d If you wear a mask during ultrasound procedures put on a mask 2 Start training mode Press for mo...

Page 11: ...in the remote control or use the buttons See also Troubleshooting on page 11 Using custom phrases When training the remote control you can use custom phrases With some voices the remote control respon...

Page 12: ...consider including the following tasks when setting up If you use voice commands put on the microphone before putting on the smock Encase the remote control in the recommended sterile sheath Or if you...

Page 13: ...ance of other electrical equipment in the vicinity Operation conditions Operation is subject to the following two conditions This device may not cause harmful interference This device must accept any...

Page 14: ...duce potential for harmful interference to co channel Mobile Satellite systems High power radars are allocated as primary users meaning they have priority of 5250 5350 MHz and 5650 5850 MHz and these...

Page 15: ...tem behaves unexpectedly for example the image unexpectedly freezes or changes make sure that it is not connected to another remote control The ultrasound system can respond from up to 30 feet away to...

Page 16: ...ring the remote control is included Contact CIVCO for additional sheaths Labeling symbols The following labeling symbols are on the product and packaging Dimensions Width 61 1 mm Height 111 1 mm Depth...

Page 17: ......

Page 18: ...P11771 01 P11771 01...

Reviews: