background image

SonoSite® Mini-Dock User Guide

The SonoSite

®

 Mini-Dock provides connections for accessories, peripherals, and the M Series ultrasound systems, 

MicroMaxx

®

 ultrasound system, or 

TITAN

®

 

high-resolution ultrasound system.

Attaching and removing the mini-dock

WARNING:

To avoid the risk of electrical shock to the patient, do not touch the ungrounded connectors on the back 
of the mini-dock while simultaneously touching a patient.

Caution:

To avoid damaging the mini-dock, do not perform high current grounding impedance testing involving 
this part. Accessible metal of the mini-dock is not protectively earthed. For an explanation on the 
grounding of the mini-dock, see SonoSite Technical Bulletin 003/06 at 

www.sonosite.com

Select 

Support and Service

 and then select your system type.

To avoid damaging equipment, remove mini-dock from system prior to transportation.

Attach mini-dock

1

Ensure that the ultrasound system is turned off.

Connecting the system and mini-dock while the power is on may cause the mini-dock to 
function improperly.

2

Slide the mini-dock feet under the ultrasound system, and firmly press the mini-dock into the 
system connector. The mini-dock is correctly attached when no gap is between the system 
and mini-dock.

Note: If at any time the ultrasound system loses connectivity, turn off the system and reattach the mini-
dock and system. Always verify that the mini-dock and system are correctly attached after changing a 
transducer. When you change a transducer, the mini-dock may loosen.

Remove mini-dock

1

Grasp the handle on ultrasound system and push back on the release lever.

2

Pull the ultrasound system forward.

Release lever

1

2

Summary of Contents for Mini-Dock

Page 1: ...pport and Service and then select your system type To avoid damaging equipment remove mini dock from system prior to transportation Attach mini dock 1 Ensure that the ultrasound system is turned off C...

Page 2: ...s or disinfectants on surfaces Immersion type disinfectants are not approved for use on surfaces Clean and disinfect The exterior surface of the mini dock can be cleaned and disinfected with a recomme...

Page 3: ...und danach den Typ Ihres Systems Um Sch den am Ger t zu vermeiden das System vor dem Transport aus dem Mini Dock entfernen Anschlie en des Mini Docks 1 Sicherstellen dass das Ultraschallsystem ausgesc...

Page 4: ...ein Eintauchen erfordern sind nicht f r die Verwendung auf Oberfl chen geeignet Reinigung und Desinfektion Die u ere Oberfl che des Mini Docks kann mit Hilfe eines empfohlenen Reinigungs oder Desinfe...

Page 5: ...tipo de sistema Para evitar da ar al equipo extraiga el m dulo de acoplamiento del equipo antes de transportarlo Conectar el m dulo de acoplamiento 1 Aseg rese de que el sistema de ecograf a est apag...

Page 6: ...endados para tratar las superficies del sistema No se han aprobado los desinfectantes de inmersi n en dichas superficies Limpiar y desinfectar La superficie exterior del m dulo de acoplamiento puede l...

Page 7: ...ervice puis choisir le type de syst me concern Pour viter d endommager le mat riel retirer le mini dock de l chographe avant le transport Fixation du mini dock 1 S assurer que l chographe est hors ten...

Page 8: ...ection recommand es sur les surfaces du mat riel L utilisation de d sinfectants de type immersion n a pas t approuv e sur les surfaces Nettoyage et d sinfection La surface externe du mini dock peut tr...

Page 9: ...di scegliere il tipo di sistema utilizzato Per evitare danni all apparecchiatura rimuovere la mini stazione dal sistema prima del trasporto Collegamento della mini stazione 1 Verificare che il sistema...

Page 10: ...ti di pulizia e disinfezione consigliati per le superfici I disinfettanti a immersione non sono stati approvati per l uso sulle superfici Pulizia e disinfezione La superficie esterna della mini stazio...

Page 11: ...e em seguida selecione o tipo do seu sistema Para evitar danos ao equipamento retire o minipedestal do sistema antes de transportar Conecte o minipedestal 1 Verifique se o sistema de ultra som est de...

Page 12: ...ipedestal pode ser limpa e desinfetada com um produto de limpeza ou desinfetante recomendado 1 Remova o sistema desconecte a fonte de alimenta o e solte os cabos 2 Use um pano macio levemente umedecid...