SONOSAX MINIR82
- User interface V4.2
Page 14 de 32
4.4
UNIT STATUS
This menu displays all the main current settings of the MINIR82, spread on 4 pages. Press the UP or DOWN
keys to scroll the pages; press LEFT key to return to the main contextual menu
POWER
Fuel gauge of the batteries in Volts and as bar-
graph; post EXTERNAL if powered from an
external power supply
HD FREE
Remaining disk space on the hard disk
HD HH :MM
Remaining recording time on the hard disk.
CF FREE
Remaining disk space on the CF card
CF HH :MM
Remaining recording time on the CF card
NOTE:
the remaining recording time depends on the configuration such as sampling rate and nr of tracks
SYNC
Audio synchronisation such as: AES, internal,
word clock or video.
FS
Sampling frequency 44.1k, 48k, 88.2k, 96k,
176.4k, 192kHz.
BIT DEPTH
Numbers of bits per sample (quantization): 24
bits, 16D bits (dithering), 16 bits.
UP/DOWN
Nominal, NTSC Corr/- 0,1% or C Mode
WAV FILE
File Format: MONO, STEREO, POLYPHONIC
MIRROR
Mirroring status on the CF Card: OFF, ON.
TIME
Current value of the Time Code
(hours: minutes: seconds)
FORMAT
Time Code format, generated or received:
23.976, 24, 25, 29.97ND, 29.97D, 30ND,
30D, AUTO, INTERNAL, UNKNOWN.
SOURCE
Source of the time code signal:
EXT JAM SYNC, EXT NO JAM, INTERNAL,
INTERNAL OUTPUT.
MODE
REC RUN, FREE RUN
ELAPSED
Elapsed time from the beginning of the Take
FILETAG
unique identifier (prefix of the file name)
PROJECT
Project name
SCENE
Scene name
TAKE
Take number
TAPE
Tape ID = Working day