SONOPAN LMC-10 Instruction Manual Download Page 2

 

TABLE OF CONTENTS 

1.

 

CHARACTERISTICS ...................................................................................................................... 1

 

1.1.

 

Equipment.............................................................................................................................. 1

 

1.1.1.

 

Basic accessories ........................................................................................................... 1

 

1.1.2.

 

Additional accessories ................................................................................................. 1

 

1.2.

 

CONFIGURATION ................................................................................................................. 1

 

1.2.1.

 

Components of luminance meter ............................................................................. 2

 

1.2.2.

 

Measurement module.................................................................................................. 3

 

1.3.

 

Technical data ....................................................................................................................... 3

 

1.3.1.

 

Spectral characteristics................................................................................................ 3

 

1.3.2.

 

Directional characteristics .......................................................................................... 4

 

1.4.

 

Temperature compensation.............................................................................................. 4

 

1.4.1.

 

Compensation of zero indication .............................................................................. 5

 

1.4.2.

 

Temperature compensation of the result............................................................... 5

 

2.

 

THE LMC-10 METER OPERATION............................................................................................ 5

 

2.1.

 

Preparations .......................................................................................................................... 5

 

2.2.

 

Measurement ........................................................................................................................ 5

 

3.

 

BASIC FUNCTIONS OF CONTROL UNIT ................................................................................. 6

 

4.

 

EXTENDED FUNCTIONS OF CONTROL UNIT........................................................................ 6

 

4.1.

 

Access to extended functions of control unit............................................................... 6

 

4.2.

 

Application: Medical monitors .......................................................................................... 7

 

4.3.

 

Application: Measurements memory .............................................................................. 7

 

4.4.

 

Application: Advanced ........................................................................................................ 7

 

4.4.1.

 

Relative measurement................................................................................................. 7

 

4.4.2.

 

Integration ...................................................................................................................... 7

 

4.4.3.

 

Statistics .......................................................................................................................... 7

 

5.

 

CALIBRATION AND ADJUSTMENT.......................................................................................... 7

 

6.

 

MAINTENANCE RECCOMENDATIONS ................................................................................... 8

 

7.

 

FIRMWARE .................................................................................................................................... 8

 

8.

 

CE MARKING AND WEE DIRECTIVE ........................................................................................ 9

 

 

Summary of Contents for LMC-10

Page 1: ...vember 2018 CONTACT LUMINANCE METER LMC 10 INSTRUCTION MANUAL PPUH SONOPAN sp z o o ul Cio kowskiego 2 2 15 950 Bia ystok Poland phone fax 48 85 742 36 62 sonopan sonopan com pl http www sonopan com p...

Page 2: ...f zero indication 5 1 4 2 Temperature compensation of the result 5 2 THE LMC 10 METER OPERATION 5 2 1 Preparations 5 2 2 Measurement 5 3 BASIC FUNCTIONS OF CONTROL UNIT 6 4 EXTENDED FUNCTIONS OF CONTR...

Page 3: ...sen measurement procedure e g to test the reproduction of the grayscale of monitors according to DICOM GSDF1 function The function of the key can be dependent on the running application of the control...

Page 4: ...surement probe P 200 measurement module LMC 10 measurement probe RF 200C interface RF200C measurement module Each of the above mentioned components of the measurement system is identifiable according...

Page 5: ...s realised with the use of the set of glass absorption filters Such a solution guarantees high long term and temperature stability especially in comparison with the cheaper realisations in which inter...

Page 6: ...em Such shape of the beam of rays is the main attribute for the LMC 10 measurement probe and its enormous advantage over other meters available on the market Therefore the influence of luminance irreg...

Page 7: ...use of the high class elements in the design of the meter the LMC 10 probe is equipped with the automatic compensation system of the influence of the environmental temperature on the measurement valu...

Page 8: ...The control devices are equipped with applications or functions that extend the range of the probe usage All the applications have the possibility of archiving of the measurements results to an exter...

Page 9: ...trol units 4 4 Application Advanced 4 4 1 Relative measurement The control units enable to conduct and archive the measurements whose results are expressed as a percentage of any reference It is possi...

Page 10: ...a vertical position The probe cap should be removed only during the measurement The probe should be removed and put on while turning it right clockwise which prevents it from being untwisted by accide...

Page 11: ...c compatibility The conformance of the above mentioned requirements is confirmed by CE mark This product cannot be thrown away with household waste Deposit the product in an authorized electrical and...