8
4046061-E
The vent hood can be reconfigured from the
factory configured vertical vent; to a hori-
zontal configuration by removing the ex-
haust cap and placing it over the vertical
outlet.
Before installing, a quality silicone
sealant should be used on the cap to pre-
vent any leakage.
The main support for the vent hood is pro-
vided by the mounting hooks on the top
panel.
Insert the top plate hooks into the slots on
the back panel. The hood will hang in place
without the need for additional support.
Replace the two (2) locking nuts and three (3) top plate fasteners to secure the unit
in to place. The vent hood is now ready for the venting phase of the installation.
Note: Remember to install the screws and nuts to secure unit into place.