  Any technical advice in verbal or written form or in any other way, is given on the basis of the 

actual knowledge, but without any warranty and / or liability. 

  A project-related, static dimensioning and the glass-technically correct use of the glasses is 

not carried out or checked by us. This is the responsibility of the system installer. 

  Special technical designs or special constructions may be subject to official approval. It is the 

responsibility of the customer or the building owner to obtain such approval. Resulting 
changes in design or additional services, in particular tests and calculation proofs, are at the 
expense of the customer. 

Fixing points of the KIOTO modules 

Detailed information about the mounting (clamping range) and the load limits can be found in 
the following file: "KIOTO_Mounting_matrix_2021". 

To resist the named snow and wind loads, the marked distances must be followed when mounting. In 
case of a longitudinal mounting, the specified mounting points must also be adhered to. If this is not 
possible because of the substructure, a crossbar system must be used! 

For standard mounting of 

modules with frame

, the modules must be securely fastened with 

continuous support profiles at least 4 points. 
The PV modules can only be attached to the substructure by clamping from the front. The clamping 
area must be at least 400 mm² per fastening point. Use a torque wrench for assembly. The tightening 
torque for an M8 screw made of V2A is 20Nm. Use suitable, corrosion-proof fastening material. 

When assembling 

modules without frame

, they must be clamped with laminate clamps. The 

minimum length for these laminate clamps is 100mm. We generally recommend vertically mounted 
laminate modules to be secured against sliding out of the laminate clamps with a slip protection when 
clamping on the long module side. The tightening torque of the laminate clamps can be found in the 
data sheet of the clamp manufacturer. 

Electrical connection of the photovoltaic generator 

 

At high direct current voltages, as can occur in serial connections, the risk of short circuits and electric 
arcs is higher. To avoid this, always use an adequate cross section for cables and connectors, which 
are approved for the maximum specified value of open circuit voltage. 

  KIOTO modules are equipped with the following junction boxes and plugs: 

Modul series 

Plug system 

Power-60 
Power-60-ALPIN 
Power-60-MAXIM 
Glas-60 framed 
Glas-60 unframed 

Stäubli MC4 

Project-60 340Wp halfcut 

MC4 

— compatible connecting system 4 mm²

 

Project-60 380Wp halfcut 

Stäubli MC4 EVO2

 

 

  The used solar cable is a 4mm² insulated, weatherproof and UV-resistant product. 

 

 

Summary of Contents for KIOTO SOLAR Glas-60 framed Series

Page 1: ...PHOTOVOLTAIC MODULES Installation manual Power 60 Standard MAXIM ALPIN Glas 60 with without frame Project 60 halfcut...

Page 2: ...ctions for mounting 4 Electrically 4 Mechanically 5 Advices double glass modules without frame 5 Fixing points of the KIOTO modules 6 Electrical connection of the photovoltaic generator 6 Detailed inf...

Page 3: ...or other abrasive liquids Do not handle the module at the junction box Do not pull the module connection cables by forces Do not drill any holes in the framework or other components of the module Do...

Page 4: ...e followed stringently Remember in de energized state high contact voltage could occur and or deadly electric arc can be generated Cover the single module with a lightproof material during the mountin...

Page 5: ...of application Ensure that there is adequate ventilation behind the modules To generate optimal output of the photovoltaic generator consider the perfect alignment and mounting angle of the photovolta...

Page 6: ...be securely fastened with continuous support profiles at least 4 points The PV modules can only be attached to the substructure by clamping from the front The clamping area must be at least 400 mm per...

Page 7: ...se high quality cables to assure a failure free operating Ensure good isolation and whether UV durability of the cables The rated voltage of the solar cable must be 1000V minimum If possible use flexi...

Page 8: ...be done by qualified persons to ensure an optimized energy yield For safety reasons and to minimize maintenance works a DC disconnector should be installed between the generator and the inverter This...

Page 9: ...n in performance Clean the modules as required and soiled with plenty of water and a soft cloth or sponge without any detergent Do not use high pressure cleaners If other additives or devices like agg...

Page 10: ...Seite 10 von 12 KIOTO_Installation_manual_2021 KIOTO Photovoltaics GmbH Solarstra e 1 9300 Sankt Veit Glan sterreich 06 2021...

Page 11: ...Seite 11 von 12 KIOTO_Installation_manual_2021 KIOTO Photovoltaics GmbH Solarstra e 1 9300 Sankt Veit Glan sterreich 06 2021...

Page 12: ...KIOTO Photovoltaics GmbH Solarstra e 1 Industriepark A 9300 St Veit Glan T 43 0 4212 28 300 0 E office kioto com www kiotosolar com...

Reviews: