20
4 Network Discovery and Webserver
Configuration : Remote Settings
This page allows you to configure how you would
like the pins on the rear panel, 15 way, remote
connector to behave.
Remote Controls
This allows you to Lock or Unlock Pins 5, 7, 10 and
14. Preventing (or allowing) connected hardware
to trigger Modes, Restore, Max Silence Time and
Source Select.
Remote Start
The Remote Start Pin 15 is pulled low when the
selected trigger occurs. This pin can either be
latched low for the duration of the alarm, or only
held low for 500ms.
Remote Start Trigger
Select the alarm on which you would like remote
start to be triggered.
Remote Relay Action
Select the condition on which you would like each
remote relay to engage.
Note:
If you select a GPI pin as a relay trigger, you
will need to set up the GPIO options accordingly,
otherwise the relay may not engage.
Note:
All options may be configured at any time.
Options which are greyed out are currently not
enforced due to other settings, such as the Physical
Config option.
Fig 4-11: RB-SD1IP Screenshot of the Webserver Remotes Page