15
Network Discovery and Webserver 4
Configuration : Level & Time Settings
Select the channel you wish to configure from the drop down list and
change its settings as required. Once you have configured all channels, hit
submit.
Silence Level
Select the desired audio level to be treated as silence.
Silence Time
Enter the desired length of time for which the signal
must be below the selected Silence Level, before an
alarm is triggered. (Format; Hrs : Mins : Secs)
Restore Time
Enter the desired length of time for which a signal
above the selected Silence Level must persist, before
an alarm state is cancelled. (Format; Hrs : Mins : Secs)
Alarm / Valid Traps
Choose to enable or disable SNMP Trap generation
following changes in alarm state for each channel.
The Alarm Trap will be generated when the signal
status becomes alarmed. The Valid Trap will be
generated when the signal status changes from
alarmed back to normal. The destinations for traps
can be configured on the SNMP configuration page.
Line Level
Channels B Left and B Right have an optional extra
+8dB of gain to allow for the connection of single
ended, consumer equipment, for these channels you
may select the appropriate line level.
Note:
All options may be configured at any time.
Options which are greyed out are currently not
enforced due to other settings, such as the Physical
Config option.
Fig 4-6: RB-SD1IP Screenshot of the Webserver Level & Time Settings Page