17
Network Discovery and Webserver 4
Configuration : Alarm Settings
Channel Mode
Control how alarm signals are handled with regard
to audio switching:
Stereo
- both Main channels are required, the unit
will attempt to switch sources if either falls silent.
Mono
- only one Main channel is required, the unit
will only attempt to switch to Auxiliary if both Main
channels fall silent.
Independent
- channel switching is handled
separately, silence on Main left/right channel will
only switch in the left/right Aux respectively.
Alarm Actions
You can configure the action that the unit will take
in each channel mode, when an alarm is triggered.
Fast Restore
Fast Restore Mode automatically lowers the
Restore times to a minimum value in instances
where all sources are Alarmed. This can allow the
unit to restore audio faster and avoid dead air for
longer than necessary.
Note:
All options may be configured at any time.
Options which are greyed out are currently not
enforced due to other settings, such as the Physical
Config option.
Fig 4-8: RB-SD1IP Screenshot of the Webserver Alarms Page