SonicWall
SuperMassive
9200/9400/9600
Getting
Started
Guide
63
•
Four
mounting
screws,
compatible
with
the
rack
design,
must
be
used
and
hand
‐
tightened
to
ensure
secure
installation.
Choose
a
mounting
location
where
all
four
mounting
holes
line
up
with
those
of
the
mounting
bars
of
the
19
‐
inch
rack
mount
cabinet.
•
A
suitably
rated
and
approved
branch
circuit
breaker
shall
be
provided
as
part
of
the
building
installation.
Follow
local
code
when
purchasing
materials
or
components.
•
Consideration
must
be
given
to
the
connection
of
the
equipment
to
the
supply
circuit.
Appropriate
consideration
of
equipment
nameplate
ratings
must
be
used
when
addressing
this
concern.
Do
not
overload
the
circuit.
•
Reliable
grounding
of
rack
‐
mounted
equipment
must
be
maintained.
Particular
attention
must
be
given
to
power
supply
connections
other
than
direct
connections
to
the
branch
circuits,
such
as
power
strips.
•
As
shipped
from
the
factory
this
SonicWall
product
includes
two
power
supplies
for
redundant
AC
power
and
added
reliability.
A
field
conversion
is
available
to
convert
to
DC
mains.
•
To
disconnect
AC
power,
both
power
cords
must
be
removed.
•
The
included
power
cord(s)
are
approved
for
use
only
in
specific
countries
or
regions.
Before
using
a
power
cord,
verify
that
it
is
rated
and
approved
for
use
in
your
location.
•
This
model
is
shipped
as
AC
mains
configuration
using
standard
3
conductor
appliance
couplers.
A
field
conversion
is
available
to
change
to
DC
mains.
The
DC
mains
connector
uses
terminal
posts
with
the
polarity
marked.
•
To
disconnect
DC
power,
an
external
properly
‐
related
disconnect
device
must
be
provided
by
building
or
rack
installation.
•
Do
not
connect
AC
configured
products
to
DC
mains,
and
do
not
connect
DC
configured
products
to
AC.
Detailed
instructions
are
provided
with
the
DC
conversion
kit.
Product
must
be
configured
as
all
DC
or
all
AC.
•
DC
rating
includes
tolerances.
Do
not
operate
product
outside
of
range
shown
on
product
label.
•
DC
configuration
includes
input
cable
with
protective
earthing
conductor
(Green
and
Yellow
wire).
This
conductor
is
required
to
be
connected
to
safety
earth
ground
of
circuit.
•
Thumbscrews
should
be
tightened
with
a
tool
after
both
installation
and
subsequent
access
to
the
rear
of
the
product.
Summary of Contents for SuperMassive 9200
Page 8: ...8 SonicWall SuperMassive 9200 9400 9600 Getting Started Guide ...
Page 24: ...24 SonicWall SuperMassive 9200 9400 9600 Getting Started Guide ...
Page 50: ...50 SonicWall SuperMassive 9200 9400 9600 Getting Started Guide ...
Page 60: ...60 SonicWall SuperMassive 9200 9400 9600 Getting Started Guide ...
Page 72: ...72 SonicWall SuperMassive 9200 9400 9600 Getting Started Guide ...
Page 73: ...SuperMassive Getting Started Guide Updated February 2017 232 000344 50 Rev A ...