![Sonic KSE-310 Instruction Manual Download Page 174](http://html1.mh-extra.com/html/sonic/kse-310/kse-310_instruction-manual_1320617174.webp)
Ⅲ
-IV-2
4-2
How to use EXTERNAL SYNC
The EXTERNAL SYNC function performs transmission of this system
synchronizing with the transmission of other equipment.
4-2-1
Connection of the EXTERNAL SYNC signal
To connect the EXTERNAL SYNC signal, input it to the J30 connector pin
number P/R.
Table 4-2
J30 connector EXTERNAL SYNC signal connection
Pin No. Signal Name
Signal Level
P
EXT_SyncTrig_in
TTL level input
R
GND
GND
4-2-2
EXTERNAL SYNC signal standard
The EXTERNAL SYNC signal standard is shown below:
(1) Standard
Fig. 4-1
EXTERNAL SYNC signal input standard
Level:
HIGH (10.0 - 3.0V)
LOW (0.5 - 0.0V)
0.1ms or more
EXTERNAL SYNC
signal input
(negative logic)
Level:
HIGH (10.0 - 3.0V)
LOW (0.5 - 0.0V)
0.1ms or more
EXTERNAL SYNC
signal input
(positive logic )