background image

 

9

 

  Press    1   button, setting delay time for exiting house. The default time is 30 Sec, you can 

set the time from 1 to 255 Sec. Press Enter button to finish the setting. 

 
 
 
 
 

  Press    2   button, setting alarm time for triggering alarm, The default time is 30 Sec, you 

can set the time from 1 to 255 Sec. Press Enter button to finish the setting. 

 
 

 

 
 
 
 

    Press    3   button, setting delay time for entering house, The default time is 30 Sec, you 

can set the time from 1 to 255 Sec. Press Enter button to finish the setting. 

 

 

 

 

 
 

(2)    123456-P Numeric key 

  : To set telephone number ( can set 6 sets phone number and each 

number up to 20 digits) 

 

EX. Press 1 Button, the LCD panel shown as below.   

 
 
 

 
 
 
 

Setting    1   ,    2   or    3 

 

: For neighbors, relative friends and family members 
 to notify in case of emergencies.

 

Setting    4     

 

: The first priority dial in case of Burglary. ( check 
 police dept if acceptable or other people)

 

Setting    5   

 

: The first priority dial in case of Fire. ( check fire 
 dept if acceptable or other people)

 

Setting    6   

 

: The first priority dial in case of Medical help. 
  ( check hospital if acceptable or other people ) 

 

 
 
 
(3) 7- MSG   

:      To set recorded message which contains 1 segment of message and maximum to 

25 seconds. If the recorded message is less than 25 Sec, press    ENTER   to end 
the recorded message. When alarm is triggered, it will play recorded voice 
message. 

                Press    7     to start message recording (it will automatically count down from 25 

Sec). 

 
 

 

 

 

Setting :  Time    
1 – Exit 

:  30   Sec 

Setting :      Time    
2 – Alarm  :  30   Sec

 

Setting :     Time    
3 – Entry  :  30    Sec 

Setting :  Phone Num :    1 

******************** 

Setting :  Message  Rec 
Sel Msg 

:  1  25  Sec 

Summary of Contents for HG-1000

Page 1: ...Wireless Security Safety System HG 1000 OWNER S MANUAL ...

Page 2: ... 5 Others 5 About the Main Console Operation 6 LCD Panel illustration 6 Function for Installer Factory Default Password 8 Function for Master Factory Default Password 14 Check Function 15 Speed Dial Function 15 Arm or Disarm via the Telephone Line 15 Auto Dialer Priority 16 LCD MSG Message Indicating on LCD 16 SR 129 Remote Control Handset 17 HG 120 PIR Motion Detector 18 HG 122 HG 123 Door Window...

Page 3: ...for a long period of time Object and Liquid Entry Take care not to drop objects or liquids on any part of the equipment Damage Requiring Service The alarm should be serviced by a qualified service personnel when The power supply cord or the plug has been damaged or Objects have fallen or liquid has been spilled onto the equipment or The equipment has been exposed to rain or The equipment does not ...

Page 4: ...ssories to the system to create a more complex system as your future needs may require Flexibility You can choose the kinds of sensors and response actions for the system Personalized Program the system to notify whoever you choose in the case of alarm activation System Package HG 1000 X 1 Main Console SR 129 X 1 Remote Control Handset HG 120 X 1 PIR Motion Detector HG 122 X 1 Door Window Detector...

Page 5: ... The Main Console must be placed near a power outlet and telephone jack because the system needed to be connected with them Setting Alarm Zones Before installation you shall have the sensors learn into Main Console via system learning mode of the Main Console This system allows to install maximum 63 wireless sensors Installing the Back up Battery Remove the battery cover of the Main Console and in...

Page 6: ...ount the console on a wall follow these steps 1 Remove the two black rubber pads and store them away for future use 2 Measure and fix screws into the wall so that the two screws fit into grooves left under removed pads 3 Connect all wire connection to the jacks on the back inside and replace to back cover 4 Set the console onto the screws and carefully allow the console to drop into the groove sec...

Page 7: ...4 LCD PANEL 13 ARMED LED INDICATOR 12 POWER LED INDICATOR 11 MIC 20 DC POWER JACK 19 TEL LINE JACK 18 TELEPHONE JACKS 10 HOME BUTTON 1 Numeric keys and keys For telephone setting included pound and star keys 2 Burglary Button SP DIAL button together with Burglary Button 3 Fire Button SP DIAL button together with Fire Button 4 Medical Emergency SP DIAL button together with Fire Button 5 SP DIAL but...

Page 8: ... approved by the party responsible for compliance could void the user s authority to operate the equipment IMPORTANT NOTE To comply with the FCC RF exposure compliance requirements no change to the antenna or the device is permitted Any change to the antenna or the device could result in the device exceeding the RF exposure requirements and void user s authority to operate the device This device c...

Page 9: ...oard locked system disabled and locked LCD shown as below It will trigger alarm but won t dial out the phone number you can use Remote Control Handset DISARM button to disarm the system 2 If the password is correct default 123456 It will have beep sound and LCD panel shown as below 3 Select the Number setting 0 SET Function menu Press 0 to start setting 1 0 T For time setting Default is 30 seconds...

Page 10: ...2 or 3 For neighbors relative friends and family members to notify in case of emergencies Setting 4 The first priority dial in case of Burglary check police dept if acceptable or other people Setting 5 The first priority dial in case of Fire check fire dept if acceptable or other people Setting 6 The first priority dial in case of Medical help check hospital if acceptable or other people 3 7 MSG T...

Page 11: ...gits and will automatically show OK max set 6 digits if the word if less than 6 digits you can press ENTER after key in the number and it will show OK Press 1 and in the change Install code menu Press 2 and in the change Master code menu 1 SEQ Sequent for code learning to set zone location First of all all the sensors need to be learned into main console and main console can receive the signal if ...

Page 12: ... First to install Battery and press PANIC button the led will light on for 1 Sec The sensor will be learned into main console 4 Panic Watch First to install Battery and press RED button the led will light on for 1 Sec The sensor will be learned into main console 5 Smoke Detector First to install Battery and press S1 button the led will light on for 1 Sec The sensor will be learned into main consol...

Page 13: ...r When sensor is faulty or needs replacement To replace the original sensor only need to key in sensor learned order number Finish the number key in and press ENTER system will ask for relearning the Sensor you can trigger the sensor and learn the sensor into the main console Note Please use the same type sensor to replace the old one Press 2 to go to replace sensor mode LCD panel shows as below O...

Page 14: ...d sensors Press 3 and go into clear mode Press 1 and key in learned sensor order code then press ENTER It will clear this sensor Press 2 It will show the Are you sure press ENTER It will clear all learned sensors Clear Sensor 1 Single 2 All Clear Sensor Clear OK Num xx Clear Sensor Are You Sure Enter Clear Sensor Waiting Clear Sensor Clear All OK Clear Sensor 1 Single Num xx ...

Page 15: ...s below A AWAY Press AWAY button to set Armed Away alert Armed LED always lights on H HOME Press HOME button to set Armed Home alert Armed LED always blinks NOTE 1 Sensors belong to 24 hours included Smoke Detector Gas Detector Panic Watch Remote Control Handset PANIC button 2 Distinguish A AWAY and H HOME mode When system is armed in HOME mode Main console will neglect the transmission Code MASTE...

Page 16: ...condition Arm or Disarm Via the Telephone Line for Tone Mode This function allows you to dial your home telephone from outside to Arm or Disarm your security system When hear a long Beep sounds after 10 rings in the phone then enter Master code 135246 default if the password is correct it will respond a long Beep sounds in the phone then to respond the system status at this moment if the password ...

Page 17: ...ayback message 2 times Medical help It will automatically dial phone 6 phone 1 phone 2 phone 3 call sequentially by 3 cycles attempt 6 1 2 3 When telephone answered it will playback message 2 times LCD MSG Message indicating on LCD This system will leave warning message on LCD panel while sensors opened or triggered or in low battery It also emits 3 short Beep at every 10 Sec to remind you in the ...

Page 18: ...button to set the system in HOME mode 5 PANIC Press this button will trigger the alarm and activate auto dialing 6 BATTERY COMPARTMENT For 12V alkaline battery Zone Address Setting Enter the Installer code and press 1 to start learning sensor into the system to press PANIC button for 1 sec the red LED also light on 1 sec the main console emits a long Beep LCD panel shows Sensor Added The sensor ha...

Page 19: ...oltage signal The red LED will blink for one sec If Main Console receives the signal will leave some message on the display 2 C OFF W SWITCH l When the switch is set on C Continue position the PIR continually detects at interval every 3 to 5 seconds after detecting the movement of human dog cat It is an idea for checking l When the switch is set on OFF position It will turn off the power the PIR d...

Page 20: ...tion when Install Motion sensors detect the movement of humans and animals within their range In order to prevent false alarms we recommend that you do not install any motion sensor in the following areas Do not install any motion sensor in the following areas l Where there is a device that causes rapid temperature change or rapid heat transfer for instance near an air conditioner fire place heate...

Page 21: ...o install the Motion Sensor please follow these steps l Take out the screws or double sided adhesive and install the mounting bracket on the wall press the ball joint portion into the bracket until it snaps securely To secure the mounting bracket to the wall at 2 meters above the floor l Put the PIR on the mounting bracket l Test the sensor by walking within its range When the sensor is triggered ...

Page 22: ... for 1 sec 3 Magnet Sensor 4 Battery Cover Remove the cover and put one 12V alkaline battery here Button function 1 Magnet 2 Magnetic Switch 3 Transmit LED When the sensor is activated LED will light for 1 sec 4 Magnet sensor 5 Battery Cover Remove the cover then put one 12V alkaline battery here Note Magnet and magnet switch needed to be placed on parallel position triangle arrow to ensure the be...

Page 23: ...ch 5 mm between the magnet sensor and the magnet otherwise the sensor will not work properly Enter the installer password and let main console in learning mode take magnet away from magnet sensor it will trigger the sensor and LED will light on for 1 sec the Main Console emits one Beep and LCD displays Sensor Added it means sensor has learned into the system successfully LCD display on the Main Co...

Page 24: ... Before exposing the adhesive backing align the two arrows on the surface where you want them installed Check that both parts of the device fit and that they can be mounted with a gap less than 1 4 inch between them refer to below picture 4 When finished the above procedure please reconfirm the setting is correct or not in main console Press the CHECK button then open the window The main console w...

Page 25: ... Also it is important to install the siren where the cable can be hidden and discreetly out of reach of potential intruders or anyone likely to tamper with the system When the siren is installed and the system is set to Arm it will emit a piercing 110 decibel siren once a sensor detector activates the alarm 1 Plug the wire into the control panel OUTPUT JACK 2 Cord length 8 meters 3 Loudness output...

Page 26: ...ference Item Descriptions Install Code Master Code Exit Time Alarm Time Entry Time Auto dialing Mode Sensor No of Learning Preset Telephone No for Auto dialing No 1 Name Tel No No 2 Name Tel No No 3 Name Tel No No 4 Burglary Emergency Name Tel No No 5 Fire Emergency Name Tel No No 6 Help Emergency Name Tel No ...

Page 27: ...y Optional Approximate 7 hours NO AC adaptor Temperature Range 0 C 40 C RF Range 150 feet in open air space Security Code Hopping code Alarm Activation Time 1 255 seconds available alarm time setting Dialing Type Tone Voice Message Playing Time Total 25 seconds Preset Telephone Numbers 6 phone numbers 20 digits for each number Material ABS Weight 650 g Dimensions 26 cm X 17 cm X 3 5 cm ...

Reviews: