LC-RL-8-W User Manua
l
Sonetonix
2
1.2 Override Input
An override input is provided to allow an external contact closure to momentarily override
the control system program and set all channels output to its override pre-set state.
1.3 Front panel
Four tactile switches on the front panel provide two functionalities. One, the Device’s S-
NET id can be programmed manually at any time, using the CH1 (1) and CH2 (2) keys. The other
functionality of these switches is to navigate through the channels manually along with channel
status indication LEDS.
1.4 Loads
Two pin detachable terminal blocks on the rear side for each channel to control the
controllable devices. Live IN (230VAC Mains @50hz) to be connected on Pin 1 and Live output
to be taken from Pin 2 and connect to Load Live.
1.5 S-NET
The LC-RL-8-W communicates with all Sonetonix products or third party units via S-NET.
A pair of S-NET terminal blocks, allow for easy
daisy-chaining of several DIN rail Series
automation control modules. 12VDC, S+, S- and Ground should be connected in each S-NET
terminal.