i)
max. discharge energy
S-50 DC ............................................................................................................................ 7500 J
S-80 DC ......................................................................................................................... 12 800 J
S-110 DC ....................................................................................................................... 18 150 J
S-120 DC ....................................................................................................................... 14 400 J
j)
operating temperature ................................................................................................... -
25…+55°C
k) storage temperature ...................................................................................................... -
40…+70°C
l)
vibration stress ............................................................................. as per DIN 68 T2-6, test group C
m) weight of operating unit ............................................................................................ approx. 13.5 kg
n) weight of high-voltage unit
S-50 DC ........................................................................................................................... 17.0 kg
S-80 DC ........................................................................................................................... 18.5 kg
S-110 DC ......................................................................................................................... 20.0 kg
S-120 DC ......................................................................................................................... 20.5 kg
o) degree of protection as per EN 60529
operating unit ........................................................................................................................ IP40
high-voltage unit .................................................................................................................... IP65
high-voltage unit at terminals ................................................................................................. IP00
p) max. voltage / discharge energy for discharge rod
S-50 DC ....................................................................................... 50 kV / 7500 J (6
µF at 50 kV)
S-80 DC .................................................................................... 80 kV / 11 250 J (4
µF at 75 kV)
S-110 DC ............................................................................... 110 kV / 15 000 J (3
µF at 100 kV)
S-120 DC ............................................................................ 125 kV / 18 750 J (2.4
µF at 125 kV)
q) dimensions
– operating unit ............................................................................. 370 x 200 x 280 mm
r) dimensions
– high-voltage unit
S-50 DC ....................................................................................................... 210 x 380 x 310 mm
S-80 DC ....................................................................................................... 210 x 400 x 310 mm
S-110 DC .................................................................................................... 210 x 420 x 310 mm
S-120 DC ..................................................................................................... 210 x 430 x 310 mm