CMP-3000 – USER MANUAL
56
5.7 Circuit continuity test
WARNING
Do not perform measurements on the circuit under the
voltage. Before the measurement disconnect the pow-
er and discharge capacitors.
To perform the continuity test:
set the rotary switch at
Ω
,
connect black test lead to
COM
terminal, and red test lead to
V
Ω
Hz%CAPTemp
terminal,
press
MODE
button, to display
Ω
on the screen,
contact the tips of test probes to the points of measurement,
read the measurement result on the display; the beep will be acti-
vated when resistance values are below approx.
50 Ω
.
5.8 Diode test
WARNING
Do not perform measurements on the circuit under the
voltage. Before the measurement disconnect the pow-
er and discharge capacitors. Do not test the diode un-
der voltage.
To perform the diode test:
set the rotary switch at
Ω
,
connect black test lead to
COM
terminal, and red test lead to
V
Ω
Hz%CAPTemp
terminal,
press
MODE
button, to display
and
V
on the screen,
contact the tips of test probes to the diode. The red test probe
should contact the anode and the black should contact cathode,
read the test result on the display
– the forward voltage is dis-
played.
For a typical silicon rectifier diode, it is approx. 0.7 V, and for
a germanium diode it is approx. 0.3 V
For LEDs with a low power, typical voltage value is in the
range of 1.2…5.0 V depending on the colour.
Summary of Contents for CMP-3000
Page 2: ......
Page 3: ...1 INSTRUKCJA OBSŁUGI CYFROWY MIERNIK CĘGOWY PRĄDU AC DC CMP 3000 Wersja 1 03 19 08 2020 ...
Page 12: ...CMP 3000 INSTRUKCJA OBSŁUGI 10 4 Opis funkcjonalny 4 1 Gniazda i funkcje pomiarowe ...
Page 39: ...37 USER MANUAL AC DC DIGITAL CLAMP METER CMP 3000 Version 1 03 19 08 2020 ...
Page 48: ...CMP 3000 USER MANUAL 46 4 Functional Description 4 1 Measuring terminals and functions ...
Page 75: ...73 MANUAL DE USO MEDIDOR DE PINZA DIGITAL AC DC CMP 3000 Versión 1 03 19 08 2020 ...
Page 84: ...CMP 3000 MANUAL DE USO 82 4 Descripción funcional 4 1 Tomas y funciones de medición ...
Page 118: ...CMP 3000 РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ 116 4 Описание функций 4 1 Разъемы и функции измерения ...
Page 143: ......