Description
14
Energy Control
Rail-DIN Receiver Zona 6 RF
N L
R6
R5
R4
R3
R2
R1
RB
RA
Pump Connection, contact closure output
Boiler Connection, contact closure output
Tab to mount on rail-DIN the receiver
Key to force ON the Zone relay
Fuse 10A (5x20mm)
LEDs
Power lighted ->
Power not lit -> disconnected to power supply
Zone relay lighted -> The relay of these zone is connected
Zone relay not lit -> The relay of these zone is disconnected
Zone relay flashing -> Receiving an order
Coding lighted -> with signal
Coding not lit -> without signal
Coding flashing -> Sending dates or SMS received
connected to power supply
The contacts of the relays are powered, with individual maximum load
of 5A and maximum load between all connected relays of 10A
OUTPUTS, SPST relays
The pump and boiler
operate only when one
of the zones has a
thermostat demand
-> Encoding that zone with the emitter
Zone relay flashing
+
Coding flashing
Z7
Make all the connections
before conect the power supply
230V~ 50/60Hz máx. 2VA + C. of relays
+10%
- 15%
Power supply connection
Press once to manually on/off
these zone`s relay.
Holding down enters in coding
mode between emitter and
receiver