background image

Statistics

Maximum Temperatures 

 (t1, t2, t3, t4)

Shows  the  maximum  temperature  reading  at  each  one  of  the  probes 
identified by their number on the display.

- Pressing           values are initiated at zero.
- Pressing                 you move on to the next value.
- Pressing           you exit of statistics menu

Minimum Temperatures

 (t1, t2, t3, t4)

Shows  the  minimum  temperature  reading  at  each  one  of  the  probes 
identified by their number on the display.

Total Operating Hours

 (r1, r2, r3, r4)

Shows  each  relay's  total  operating  hours  since  the  installation  was 
carried out. 

This statistical information cannot be set at zero.

temperature reading and in statistics an error message is shown .

 Those probes that are not connected do not give out any 

To enter statistics menu press 

        

5 seconds (screen  lighted),screen shows the first statistic

.

In this menu you will find all the data saved by conytrol from its initial functioning and with 
which you will be able to optimise your installation, as you will be given data regarding  times of 
operation, maximum, minimum & average temperatures. All these data will allow you to assess 
your installation performance depending on meteorological conditions and your configuration.

Average Temperatures

 (t1, t2, t3, t4)

Reports  the  average  temperature  reading  of  each  of  the  probes 
identified by their number on the screen.

Partial Operating Hours

 (r1, r2, r3, r4)

Shows the hours of operation of each relay since the last time it was 
reset. They are identified by their number on the screen.

S S

2

3

4

4

Sonder

ESC

OK

Enables or disables the function to regulate the temperature of a 
probe (heating, boiler, underfloor heating, ...) and allows setting 
their values.

Warnings & Warranty Conditions

rE  type:

  The  relay  disconnects  when  the  temperature  falls  to  the  setpoint  and 

will connect when it rises to the setpoint plus differential.

CA type:

 It disconnects when the setpoint is reached and will connect when the 

temperature falls to setpoint minus differential. 

Differential 

(

diFt

): Temperature values between connection & disconnection of 

the relay.

Maximum limit setpoint 

(

HSPo

)    : Maximum value that can set the setpoint.

Minimum limit setpoint 

(

LSPo

)     :  Minimum value that can set the setpoint.

The relay is activated  (rELE): 

Sets the relays that is activated. Control 

322 

(r1, r2), 

333 

(r1, r2, r3) y 

344 

(r1, r2, r3, r4)

Icons relays (ICon): 

Assign a distinctive icon for each relay. The display will show the 

temperature, the icon assigned and the number of relay is activated.

Minimum off  time 

(

doFF

): Delay time applied when  the compressor stops and 

which prevents the compressor restarting even if conditions for this are met. This 
delay is also applied after switching on the thermostat to protect the compressor 
in the event of a power outage.

Defrost  timer  (dit)

:  Interval  between  the  start  of  two  successive  defrosts   

expressed in hours.

Time-out  defrost  finish  (dEt)

:  After  this  time  has  elapsed  (in  minutes)  defrost 

finishes.  Zero  indicates  defrost  disabled.  “

dEF

”  appears  on  the  display  during 

defrost. 

Individual settings for each thermostat function

Defines the type of probe connected for each input. Every time you 
change the type for the probe make that the settings for HSPo, 
LSPo and set point returns to factory settings if the new settings 
are out of range for the new type of probe. Once open selected the 
probe, set Pt1 for connect a PT1000 or PtC2 to connect PTC2000.

Defines the type of display illumination. On solid (parameter On) 
or time (parameter OFF). It turns off when 15 minutes of inactivity 
on the keyboard, pressing any key lights up again.

Prevents  access  to  configuration,  allowing  the  user  to  see 
statistics, display light,  and probe and relays test.

Scale: 

Pt1(PT1000) / PtC2(PTC2000)  

Factory set:  

PtC2

Menu

Make sure that the environmental conditions are adequate before installing the regulator, as well as working temperature, 

humidity, pollution and gas emission, since any of these factors may affect the correct operation of the product. For any 
handling during either installation or repairing procedures the regulator should be disconnected from the electric grid.

The electrical connections must be those indicated in this manual and the label in device. Assembly, electrical connection, 

set-up, and maintenance should be carried out only by qualified technicians. The connections referred to in this manual are 
those of the regulator; to connect the rest of the installation components, the user should check the technical instructions 
for each piece of equipment (collectors, tanks, valves, etc.). For a correct operation, make sure that the technical features of 
the  elements  &  the  installation  are  compatible  and  complies    normative.  If  possible  defects  are  detected  that  may 
jeopardise or lead to incorrect operation of your installation, it is recommended not to connect this device.

Total or partial reproduction of this document is forbidden by any means without prior consent in writing by SONDER 

REGULATION  S.A.  The  graphics  and  information  in  this  manual  are  illustrative  and  they  might  include  technical  or 
typographic mistakes. Sonder Regulación S.A. reserves the right to make any changes to the product, the technical data, or 
the assembling instructions, without prior notice.

RAIL  322/333/344  is  an  independent  control  device  to  mount  on  Rail-DIN  inside  an  electrical  panel  to  provide  it  of 

insulation and cables should be channelled in tubes or gutters to be properly installed. This regulator is not a safety device, 
neither can be used as such; it is the responsibility of the person in charge to include adequate protection for each type of 
installation (

complying with the standards, HOMOLOGATED

).

We disclaim all responsibility for damaged devices as a result of 
improper handling, omission of warnings given in this manual, 
or lack of technical knowledge as to the needs of the installation.

If repairs are out of warranty, the user will be inform of their 
feasibility & costs of those repairs. Assessment by our technical 
department might result in an additional cost for the user.

This device's warranty covers 3 years. This warranty is limited to 
replacement of the defective part, which will be delivered in the 
same material conditions as they were received, not responding 
for  packaging,  batteries,  instructions,  or  any  other  accessory 
that  this  product  includes,  and  that  is  not  included  in  the 
delivery note. 

For any repair covered by this warranty it is necessary to present 
the documentation proving the purchase of this product within 
the  period  of  time  covered  by  the  warranty  herein,  together 
with a description made by the user as accurate as possible of 
the defect or anomalous operation of the product.

- Devices modified without prior consent on the part of 

the manufacturer.

-  Devices  damaged  either  by  impacts  or  liquid  or 

gaseous  spillage  or  emissions.  Devices  presenting 
natural wear-and-tear or because of improper use of 
the device.

- Those costs resulting from delivery or reception of 

material.

-  Demands  of  compensation  due  to  loss  of  profit, 

compensation  for  utilization  as  well  as  indirect 
damages,  as  long  as  these  are  not  of  obligatory 
liability in compliance with the law.

-  Devices  with  serial  number  damaged,  deleted  or 

modified.

-  Devices connected  or  used  without  complying with 

the instructions included in the device package. 

Out of warranty:

Type of Probes (t1 - t4) 

Display Light

Scale:   

On / OFF         

Factory set:    

OFF

Password

Scale:   

1   

to   

168 hours         

Factory set:    

24

Scale:   

0  

to  

99 minutes         

Factory set:    

0

Scale:   

to   

15 minutes         

Factory set:    

2

Scale:      

                                                          

Factory set:    

Scale:   

r1, r2, r3, r4         

Factory set:    

r1

Control type (C-H) refrigeration rE / heating cA

Scale with PTC2000:   

-40 a +140°C         

Scale:   

rE  / CA         

Factory set:    

rE

Thermostat 1

Scale:   

On / OFF         

Factory set:    

On

Enables or disables the function to regulate the temperature of a 
probe (heating, boiler, underfloor heating, ...) and allows setting 
their values.

Thermostat 2

Scale:   

On / OFF         

Factory set:    

OFF

Enables or disables the function to regulate the temperature of a 
probe (heating, boiler, underfloor heating, ...) and allows setting 
their values.

Thermostat 3

Scale:   

On / OFF         

Factory set:    

OFF

Enables or disables the function to regulate the temperature of a 
probe (heating, boiler, underfloor heating, ...) and allows setting 
their values.

Thermostat 4

Scale:   

On / OFF         

Factory set:    

OFF

HSPo values and LSPo are interlinked, so that the limit can not be below the minimum 

limit value and the lower limit value can not rise above the maximum limit, this could 
block the regulation scale parameters. If HSPo and LSPo is set to the same value, the 
setpoint is locked, so the user can not change the password if enabled.

Scale:   

On / OFF         

Factory set:    

OFF

Allows adjusting reading to each probe. Check temperature with 
pattern  precision  thermometer  and  then  adjust  reading  to  this 
temperature.

Scale:  

-10,0  

 to   

+10,0°C         

Factory set:    

0,0°C

Probe Calibration (t1 - t4) 

Scale:    

0,3

 to 

25,0°C         

Factory set:    

1,0°C

In menu you can enable or disable the functions of thermostats, choose the probes type to connect (PT1000/PTC2000), calibrate the readings of the probes, define the backlight and set a password. 
Depending on the model will have 2, 3 or 4, independent thermostat functions with individual settings, identified by number and can assign different icons. By default only thermostat 1 is active with factory 
settings and the other thermostats are set in deactivated.

Scale with PT1000:     

-50 a +200°C         

Factory set:    

-40,0°C

Scale with PTC2000:   

-40 a +140°C         

Scale with PT1000:     

-50 a +200°C         

Factory set:    

100,0°C

Reading Probe (Sond):

 Sets the probe reading to the thermostat. Control 

322 

(t1, 

t2) 

333 

(t1, t2, t3) and 

344 

(t1, t2, t3, t4)

Scale:   

t1, t2, t3, t4         

Factory set:    

t1

Reviews: