        In the case of broken wires, wire the wires as shown in the figure. If the product itself has no leads, the 

core color is for reference. 

        Communication Protocol 

        The product uses RS485 MODBUS-RTU standard protocol format, all operation or reply commands 

are hexadecimal data. The default device address is 1 when the device is shipped, the default baud rate is 

9600, 8, n, 1   

        1. Read Data (Function id 0x03) 

        Inquiry frame (hexadecimal), sending example: Query 1# device 1 data, the host computer sends the 
command:01 03 00 00 00 03 05 CB . 

Device ID 

Function id 

Start Address 

Data Length 

CRC16 

01 

03 

00 00 

00 03 

05 CB 

        For the correct query frame, the device will respond with data:01 03 06 00 7B 00 00 00 00 C5 7F , the 

response format is parsed as follows:   

Device ID 

Function id 

Data Length 

Data 1 

Data 2 

Data 3 

Check Code 

01 

03   

06 

00 79 

00 7A 

00 7B 

C5 7F 

        Data Description: The data in the command is hexadecimal. Take data 1 as an example. 00 79 is 

converted to a decimal value of 121. If the data magnification is 100, the actual value is 121/100=1.21. 

Others and so on. 

        2. Data Address Table 

Address 

Start Address 

Description 

Data type 

Value range 

40001 

00 00 

soil temperature 

Read Only 

0~65535 

40002 

00 01 

temperature 

Read Only 

0~65535 

40003 

00 02 

humidity 

Read Only 

0~65535 

40101 

00 64 

model code 

read/write 

0~65535 

40102 

00 65 

total points 

read/write 

1~20 

40103 

00 66 

Device ID 

read/write 

1~249 

40104 

00 67 

baud rate 

read/write 

0~6 

40105 

00 68 

mode 

read/write 

1~4 

40106 

00 69 

protocol 

read/write 

1~10 

        3 read and modify device address 
        (1) Read or query device address 

        If you don't know the current device address and there is only one device on the bus, you ca n use the 

command FA 03 00 64 00 02 90 5F Query device address. 

Device ID 

Function id 

Start Address 

Data Length 

CRC16 

FA 

03 

00 64 

00 02 

90 5F 

        FA is 250 for the general address. When you don't know the address, you can use 250 to get the real 

device address, 00 64 is the device model register. 

        For the correct query command, the device will respond, for example the response data is: 01 03  02 

07 12 3A 79, the format of which is as shown in the following table:  

Device ID 

Function id 

Start Address 

Model Code 

CRC16 

01 

  03 

02 

55 3C 00 01 

3A 79 

        Response should be in the data, the first byte 01 indicates that the real address of the current device  is, 

55 3C converted to decimal 20182 indicates that the current device main model is 21820, the last two bytes 

00 01 Indicates that the device has a status quantity. 

Summary of Contents for SM3691B

Page 1: ...echnical Parameters Technical parameter Parameter value Brand SONBEST Moisture Temperature range 30 80 Moisture Temperature accuracy 0 5 25 Temperature measuring range 30 80 Temperature measuring accuracy 0 5 25 Humidity measuring range 0 100 RH Humidity accuracy 3 RH 25 Communication Interface RS485 Default baud rate 9600 8 n 1 Power DC9 24V 1A Running temperature 40 80 C Working humidity 5 RH 90...

Page 2: ...rt Address Description Data type Value range 40001 00 00 soil temperature Read Only 0 65535 40002 00 01 temperature Read Only 0 65535 40003 00 02 humidity Read Only 0 65535 40101 00 64 model code read write 0 65535 40102 00 65 total points read write 1 20 40103 00 66 Device ID read write 1 249 40104 00 67 baud rate read write 0 6 40105 00 68 mode read write 1 4 40106 00 69 protocol read write 1 10...

Page 3: ...will respond for example the response data is 01 03 02 00 03 F8 45 the format of which is as shown in the following table Device ID Function id Data Length Rate ID CRC16 01 03 02 00 03 F8 45 coded according to baud rate 03 is 9600 ie the current device has a baud rate of 9600 2 Change the baud rate For example changing the baud rate from 9600 to 38400 ie changing the code from 3 to 5 the command i...

Page 4: ...ss Destination CRC16 01 06 00 6B 00 64 F9 FD After the operation is successful the device will return information 01 06 00 6B 00 64 F9 FD the parameters take effect immediately after successful change Disclaimer This document provides all information about the product does not grant any license to intellectual property does not express or imply and prohibits any other means of granting any intelle...

Reviews: