                SM3691B    Us er Ma nual                   

http://www.sonbus.com/ 

Sha nghai Son

best Industrial Co., Ltd                                                                             Page1

 

 

 

SM3691B 

 

 

User Manual   

 

File Version: V21.12.16

   

        SM3691B using the standard    RS485 bus MODBUS-RTU protocol,easy access to PLC

DCS and 

other instruments or systems for monitoring soil temperature,temperature,humidity state quantities.The 

internal use of high-precision sensing core and related devices to ensure high reliability and excellent 

long-term stability,can be customized 
RS232,RS485,CAN,4-20mA,DC0~5V\10V,ZIGBEE,Lora,WIFI,GPRS and other output methods. 

        Technical Parameters 

Technical parameter 

Parameter value 

Brand 

SONBEST 

Moisture Temperature range 

-30

~80

 

Moisture Temperature accuracy 

±

0.5

  @25

 

Temperature measuring range 

-30

~80

 

Temperature measuring accuracy 

±

0.5

  @25

 

Humidity measuring range 

0~100%RH 

Humidity accuracy 

±

3%RH @25

 

Communication Interface 

RS485 

Default baud rate 

9600 8 n 1 

Power 

DC9~24V 1A 

Running temperature 

-40~80°C 

Working humidity 

5%RH~90%RH 

 

 

        Wiring instructions 

        Any incorrect wiring can cause irreversible damage to the product. Please carefully wire the cable as 

follows in the case of power failure, and then connect the cable to confirm the correctness and then use it 

again.   

ID 

Core color 

Identification 

Note 

Red 

V+ 

Power + 

Green 

V- 

Power - 

Yellow 

A+ 

RS485 A+ 

Blue 

B- 

RS485 B- 

                                     

Summary of Contents for SM3691B

Page 1: ...echnical Parameters Technical parameter Parameter value Brand SONBEST Moisture Temperature range 30 80 Moisture Temperature accuracy 0 5 25 Temperature measuring range 30 80 Temperature measuring accuracy 0 5 25 Humidity measuring range 0 100 RH Humidity accuracy 3 RH 25 Communication Interface RS485 Default baud rate 9600 8 n 1 Power DC9 24V 1A Running temperature 40 80 C Working humidity 5 RH 90...

Page 2: ...rt Address Description Data type Value range 40001 00 00 soil temperature Read Only 0 65535 40002 00 01 temperature Read Only 0 65535 40003 00 02 humidity Read Only 0 65535 40101 00 64 model code read write 0 65535 40102 00 65 total points read write 1 20 40103 00 66 Device ID read write 1 249 40104 00 67 baud rate read write 0 6 40105 00 68 mode read write 1 4 40106 00 69 protocol read write 1 10...

Page 3: ...will respond for example the response data is 01 03 02 00 03 F8 45 the format of which is as shown in the following table Device ID Function id Data Length Rate ID CRC16 01 03 02 00 03 F8 45 coded according to baud rate 03 is 9600 ie the current device has a baud rate of 9600 2 Change the baud rate For example changing the baud rate from 9600 to 38400 ie changing the code from 3 to 5 the command i...

Page 4: ...ss Destination CRC16 01 06 00 6B 00 64 F9 FD After the operation is successful the device will return information 01 06 00 6B 00 64 F9 FD the parameters take effect immediately after successful change Disclaimer This document provides all information about the product does not grant any license to intellectual property does not express or imply and prohibits any other means of granting any intelle...

Reviews: