value plus 100 correction operation command is:01 06 00 6B 00 64 F9 FD .   

Device ID 

Function id 

Start Address 

Destination 

CRC16 

01 

06 

00 6B 

00 64 

F9 FD 

        After the operation is successful, the device will return information: 01 06 00 6B 00 64 F9 FD, the 

parameters take effect immediately after successful change. 

        Disclaimer 

        This document provides all information about the product, does not g rant any license to intellectual 

property, does not express or imply, and prohibits any other means of granting any intellectual property 
rights, such as the statement of sales terms and conditions of this product, other issues. No liability is 

assumed. Furthermore, our company makes no warranties, express or implied, regarding the sale and use 

of this product, including the suitability for the specific use of the product, the marketability or the 

infringement liability for any patent, copyright or other in tellectual property rights, etc. Product 

specifications and product descriptions may be modified at any time without notice.  

        Contact Us 

        Company: Shanghai Sonbest Industrial Co., Ltd   

        Address:Building 8,No.215 North east road,Baoshan District,Shanghai,China  

        Web: http://www.sonbest.com  

        Web:    http://www.sonbus.com   
        SKYPE:  soobuu   

        Email: [email protected] 

        Tel: 86-021-51083595 / 66862055 / 66862075 / 66861077 

 

Summary of Contents for SM2130B-H2

Page 1: ...9 24V 1A Dimensions 110mm 85mm 42mm Wiring instructions Any incorrect wiring can cause irreversible damage to the product Please carefully wire the cable as follows in the case of power failure and then connect the cable to confirm the correctness and then use it again ID Core color Identification Note 1 Red V Power 2 Green V Power 3 Yellow A RS485 A 4 Blue B RS485 B In the case of broken wires wi...

Page 2: ...FA is 250 for the general address When you don t know the address you can use 250 to get the real device address 00 64 is the device model register For the correct query command the device will respond for example the response data is 01 03 02 07 12 3A 79 the format of which is as shown in the following table Device ID Function id Start Address Model Code CRC16 01 03 02 55 3C 00 01 3A 79 Response ...

Page 3: ...queried accordingly Modified 5 Read Correction Value 1 Read Correction Value When there is an error between the data and the reference standard we can reduce the display error by adjusting the correction value The correction difference can be modified to be plus or minus 1000 t hat is the value range is 0 1000 or 64535 65535 For example when the display value is too small we can correct it by addi...

Page 4: ...ng any intellectual property rights such as the statement of sales terms and conditions of this product other issues No liability is assumed Furthermore our company makes no warranties express or implied regarding the sale and use of this product including the suitability for the specific use of the product the marketability or the infringement liability for any patent copyright or other intellect...

Reviews: