S201 AFM
3 - EMERGENCY PROCEDURES
3.3 - ENGINE FAILURES
27/06/2019
SONAIR-S2-D-MAN-006
Page : 3-5
Rev. : A
3.3.2
ENGINE FIRE / FAILURE DURING TAKE-OFF CLIMB
1. Throttle position
- check Full Power
2. Main and Auxiliary fuel pumps
- check on
3. Fuel selector valve
- change to opposite tank
4. Turnkey position
- check both ignition channels on.
If engine does not provide enough power, otherwise go to 7
5. Perform emergency landing
–
refer to 3.3.4 EMERGENCY LANDING WITH
If engine continues to run irregularly but able to maintain 65 KIAS level flight
6. Cabin heat
- close
7. Land as soon as practical.
8. ELT (optional equipment) - on
CAUTION
Minimum altitude recommended for short circuit in case of engine failure is
500 ft AGL
CAUTION
Maximum bank angle allowed with Flaps T/O at 65 KIAS is 40°. Failing to
maintain this speed will lead to stall and/or spin.