5
starting measurement.
Note: In the 200 Ω
measurement range, short the probe cables
in order to measure the resistance of the
cable then deduct it from the figure actually
measured.
Measurement limit Resolution
Accuracy
200 Ω
0,1 Ω
±(0.8% offset ± 5 digits)
2 kΩ
1 Ω
±(0.8% offset ± 3 digits)
20 kΩ
10 Ω
200 kΩ
100 Ω
2 MΩ
1 kΩ
±(1.0% offset ± 15 digits)
Over-voltage protection: 250 V DC or 250 V
AC RMS
Battery and fuse replacement
If the “
” icon appears on the display, the
batteries require replacing. The fuse only
needs to be replaced rarely due to errors
associated with use. Prior top replacing
the battery/fuse, turn off the instrument
and unplug the probe cables. For battery
replacement, use a screwdriver to remove
the screw from the rear panel, or both screws
for fuse replacement. Replace the fuse/
battery. Observe the correct polarity.
Warning:
Before opening the instrument, make sure
that the probe cables have been removed
from the measuring circuit.
Replace and tighten the screws so that the
device operates in a stable manner during
use and accident hazards are avoided.
Accessories:
• Instructions for Use • probe
cable • 9 V (6F22) battery • box
DISPOSAL
Waste equipment must be collected
and disposed separately from
household waste because it may
contain components hazardous to the
environment or health. Used or waste
equipment may be dropped off free of charge
at the point of sale, or at any distributor which
sells equipment of identical nature and
function. Dispose of product at a facility
specializing in the collection of electronic
waste. By doing so, you will protect the
environment as well as the health of others
and yourself. If you have any questions,
contact the local waste management
organization. We shall undertake the tasks
pertinent to the manufacturer as prescribed
in the relevant regulations and shall bear any
associated costs arising.
DISPOSING OFALKALINEAND
RECHARGEABLE BATTERIES
Batteries, whether alkaline or rechargeable,
must not be handled together with regular
household waste. It is the legal obligation of
the product’s user to dispose of batteries at
a nearby collection center or at a retail shop.
This ensures that the batteries are ultimately
neutralized in an environment-friendly way.
Specifications
• power supply: 9 V (6F22) battery
• display: LCD, up to 1999 digits
• reading over measurement limit:
a number “1” on display
• polarity indication: “-” is displayed for
negative polarity.
• operating temperature: 0 – 40 °C, max.
80% RH
• exhausted battery: “ “ icon appears on
the display.
• fuse: F 200 mV / 250 V (quick blow)
• dimensions: 140 × 73 × 30 mm
• weight: approx. 170 g (including battery)
Summary of Contents for home VC 830L
Page 19: ...19...