CLEANING
In order to ensure optimum functioning, the unit may require cleaning at least once a month, depending on the manner of use and degree
of contamination.
1.
Prior to cleaning switch off and power off the unit by unplugging it from the electric outlet!
2.
Use a slightly moistened cloth to clean the unit's exterior. Do not use any aggressive cleaners. Avoid getting water inside of and on the
electric components of the appliance!
3.
Remove the water tank. By loosening the water outlet screw, empty the water from the device. Clean the inside of the device with a dry,
lint-free cloth.
4.
Reinstall the fan!
TROUBLESHOOTING
Waste equipment must not be collected separately or disposed of with household waste because it may contain components
hazardous to the environment or health. Used or waste equipment may be dropped off free of charge at the point of sale, or at any
distributor which sells equipment of identical nature and function. Dispose of product at a facility specializing in the collection of
electronic waste. By doing so, you will protect the environment as well as the health of others and yourself. If you have any
questions, contact the local waste management organization. We shall undertake the tasks pertinent to the manufacturer as
prescribed in the relevant regulations and shall bear any associated costs arising.
TECHNICAL
PARAMETERS
power supply: . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230 V ~ / 50 Hz / 90 W
protection class: . . . . . . . . . . . . . . . . . . . . . . . . . . II.
fan blade diameter: . . . . . . . . . . . . . . . . . . . . . . . . 40 cm
3
maximum air mass volume:. . . . . . . . . . . . . . . . . . F = 68,53 m /min
fan input power:. . . . . . . . . . . . . . . . . . . . . . . . . . . P = 40,01 W
3
service value: . . . . . . . . . . . . . . . . . . . . . . . . . . . . SV = 1,71 (m /min)/W
power consumption in standby mode:. . . . . . . . . . P = 0,26 W
SB
fan acoustic power level: . . . . . . . . . . . . . . . . . . . . L = 53,57 dB(A)
WA
maximum air speed: . . . . . . . . . . . . . . . . . . . . . . . c = 3,17 m/sec
service value standard: . . . . . . . . . . . . . . . . . . . . . IEC 60897:1986 (corr. 1992)
water tank volume: . . . . . . . . . . . . . . . . . . . . . . . . 3 l (12 h humidifying)
length of power cable: . . . . . . . . . . . . . . . . . . . . . . 1,6 m
outside dimensions:. . . . . . . . . . . . . . . . . . . . . . . . 43 x 121 x 38 cm
weight: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 kg
Malfunction
Possible solution
Fan doesn’t switch on.
Check the power supply.
The fan doesn’t respond to the remote control signals. Operation range of the remote control is max. 6 m.
Replace the batteries of the remote control.
Humidifying is not working.
Fill up the water tank with ionized water.