Function button:

 - Press the         button in the measurement state to switch between the 

   PS1 and PS2 settings.

 - Long press the        button for 5S in the measurement state to enter the 

   setting state.

 - Press the        button while the measurement status or setting value is 

   modified. Confirm that the current modification  is saved and switch to 

   the next menu.

Batch button:

- Short press the        button in the measurement state to switch to the 

  batch/total view mode. At this time, the BA.S light is on, 

  the upper row shows the batch/total counting value, and the lower row 

  shows the batch/total setting value.

- Long press the        button in the measurement state, and the batch/total 

  counting value is reset to zero.

* CI4 series products do not have batch/total counting function, no such 

  button.

Modify button:

- In the measurement state, short press the          button or the        

   button to select the setting value to be modified.Press the          button 

   to enter the modification state of the current setting value (the LED 

   flashes at this time), continue to press the           button to make

   the flashing position moving left for one bit.

- Short press the          button in the setting state or setting value 

modification state to change the setting content or increase the 

flashing digit by one bit.

- Short press the          button in the setting state or setting value 

modification state to change the setting content or decrease the 

flashing digit by one bit.

Reset button:

Press the         button in the measurement state, the output is reset, and

the counting value is reset to the initial value.

+24V

5.4kΩ

Internal circuit

OV

CI Series

Counter

B.Contact access (counting speed should be set to 1cps, 30cps)

+24V

5.4kΩ

Internal circuit

OV

NPN no voltage input

Switch contact

CI Series

2-1. Input logic: no voltage input (NPN)

Counter   

Sensor 

Sensor 

A.Solid state input (standard sensor: NPN output type sensor)

A. Solid state input(standard sensor: NPN output type sensor)

+24V

5.4kΩ

Internal circuit

OV

PNP voltage input

CI series

2-2.Input logic:voltage input(PNP)

Counter 

Sensor

+24V

INA

GND

24V

INA

GND

INA

GND

+24V

5.4kΩ

Internal circuit

OV

CI Series

Counter

B.Contact access (counting speed should be set to 1cps, 30cps)

A.Relay output(standard)

B.Transistor output(to be ordered)

Switch contact

Sensor 

INA

GND

Counter

Loading

Counter

Loading

Power

(DC)

Loading 

Power

(+)

(-)

Loading

7. Input Connection

1.Product wiring diagram (if there is a difference with the instrument

 wiring diagram, please refer to the instrument wiring diagram

2. Input Connection

3. Output Connection

 6

Dimension 

CN7W Series

CN4W Series

CN8W Series

RS485

+24V

+24V

100~240V

AC/DC

RS485

100~240V

AC/DC

20

19

18

17

16

15

14

13

12

11

INB

INA

GND

RESET

+24V

INHIBIT

BATCH

RESET

BATCH

OUT1

OUT2

10 

1

RS485

100~240V

AC/DC

CN4W:(48*48)

CN7W:(72*72)

CN8W:(48*96)

48
72
96

Model

A

H(Min)

G

B

C

D

E

F

J

48
72
48

3
3
3

94.5
94.5
94.5

45.5
67.5

90

25
25
25

45.5
67.5

45

45
67

44.5

K(Min)

25
25
25

Panel 

Size

Side

Dimension

Hole

Dimension

A

B

C

E

D

F

G

K

J

+0.5

-0

(-0,+0.5)

H

97.5
97.5
97.5

MD

MD

MD

MD

BA

BA

BA

RST

3

4

5. Panel Indication

Measured value display (red LED)

- Measurement status: Displays the 

count value (default). Displays the 

batch or total when the ACCUMAGE 

menu(ACCUM) setting is BATCH.1 

or TOTAL.1.

- Setting status: Display setting 

Setting value display  (green LED)

- Measuring status: Display setting  

value (default).The counting value is 

displayed when theaccumulation menu 

(ACCUM) is set to BATCH.1

or TOTAL.1.

- Setting Status: Displays the contents 

of the settings.

Setting value indicator:   

When PS1 light is on: Displays the OUT1 setting value. 

When PS2 light is on: Displays the OUT2 setting value. 

When BA.S light is on: Displays the batch/total setting value.

When OUT1 light is on: the first counting output action.

When OUT2 light is on: the second counting output action.

When BA.O light is on: the batch/total output action.

Lock button indicator:

When the lock function is selected through the LOCK menu, 

the indicator is always on.

8. Menu operation

1

Menu state transition diagram

Measurement 

status

Se�ng status

Change 

batch 

settings

Setting value 

modification status

Reset counting value

Reset batch/total 

counting value

CI4 series products has no batch 

/ total  Volume counting function

3s

MD

MD

MD

MD

MD

BA

BA

RST

Batch count 

display mode

Remark 1) In the state of changing the preset value, if no button is pressed 

for 60 seconds, it will automatically return to the running state, and the 

setting data will not be saved.

CN7 SERIES COUNTER