Function button:
- Press the button in the measurement state to switch between the
PS1 and PS2 settings.
- Long press the button for 5S in the measurement state to enter the
setting state.
- Press the button while the measurement status or setting value is
modified. Confirm that the current modification is saved and switch to
the next menu.
Batch button:
- Short press the button in the measurement state to switch to the
batch/total view mode. At this time, the BA.S light is on,
the upper row shows the batch/total counting value, and the lower row
shows the batch/total setting value.
- Long press the button in the measurement state, and the batch/total
counting value is reset to zero.
* CI4 series products do not have batch/total counting function, no such
button.
Modify button:
- In the measurement state, short press the button or the
button to select the setting value to be modified.Press the button
to enter the modification state of the current setting value (the LED
flashes at this time), continue to press the button to make
the flashing position moving left for one bit.
- Short press the button in the setting state or setting value
modification state to change the setting content or increase the
flashing digit by one bit.
- Short press the button in the setting state or setting value
modification state to change the setting content or decrease the
flashing digit by one bit.
Reset button:
Press the button in the measurement state, the output is reset, and
the counting value is reset to the initial value.
+24V
5.4kΩ
Internal circuit
OV
CI Series
Counter
B.Contact access (counting speed should be set to 1cps, 30cps)
+24V
5.4kΩ
Internal circuit
OV
NPN no voltage input
Switch contact
CI Series
2-1. Input logic: no voltage input (NPN)
Counter
Sensor
Sensor
A.Solid state input (standard sensor: NPN output type sensor)
A. Solid state input(standard sensor: NPN output type sensor)
※
+24V
5.4kΩ
Internal circuit
OV
PNP voltage input
CI series
2-2.Input logic:voltage input(PNP)
Counter
Sensor
+24V
INA
GND
24V
INA
GND
INA
GND
+24V
5.4kΩ
Internal circuit
OV
CI Series
Counter
B.Contact access (counting speed should be set to 1cps, 30cps)
A.Relay output(standard)
B.Transistor output(to be ordered)
Switch contact
Sensor
INA
GND
Counter
Loading
Counter
Loading
Power
(DC)
Loading
Power
(+)
(-)
Loading
7. Input Connection
1.Product wiring diagram (if there is a difference with the instrument
wiring diagram, please refer to the instrument wiring diagram
2. Input Connection
3. Output Connection
6
.
Dimension
CN7W Series
CN4W Series
CN8W Series
RS485
+24V
+24V
100~240V
AC/DC
RS485
100~240V
AC/DC
20
19
18
17
16
15
14
13
12
11
INB
INA
GND
RESET
+24V
INHIBIT
BATCH
RESET
BATCH
OUT1
OUT2
10
9
8
7
6
5
4
3
2
1
RS485
100~240V
AC/DC
CN4W:(48*48)
CN7W:(72*72)
CN8W:(48*96)
48
72
96
Model
A
H(Min)
G
B
C
D
E
F
J
48
72
48
3
3
3
94.5
94.5
94.5
45.5
67.5
90
25
25
25
45.5
67.5
45
45
67
44.5
K(Min)
25
25
25
Panel
Size
Side
Dimension
Hole
Dimension
A
B
C
E
D
F
G
K
J
+0.5
-0
(-0,+0.5)
H
97.5
97.5
97.5
MD
MD
MD
MD
BA
BA
BA
RST
3
4
5. Panel Indication
Measured value display (red LED)
- Measurement status: Displays the
count value (default). Displays the
batch or total when the ACCUMAGE
menu(ACCUM) setting is BATCH.1
or TOTAL.1.
- Setting status: Display setting
Setting value display (green LED)
- Measuring status: Display setting
value (default).The counting value is
displayed when theaccumulation menu
(ACCUM) is set to BATCH.1
or TOTAL.1.
- Setting Status: Displays the contents
of the settings.
Setting value indicator:
When PS1 light is on: Displays the OUT1 setting value.
When PS2 light is on: Displays the OUT2 setting value.
When BA.S light is on: Displays the batch/total setting value.
When OUT1 light is on: the first counting output action.
When OUT2 light is on: the second counting output action.
When BA.O light is on: the batch/total output action.
Lock button indicator:
When the lock function is selected through the LOCK menu,
the indicator is always on.
8. Menu operation
1
、
Menu state transition diagram
Measurement
status
Se�ng status
Change
batch
settings
Setting value
modification status
Reset counting value
Reset batch/total
counting value
CI4 series products has no batch
/ total Volume counting function
3s
MD
MD
MD
MD
MD
BA
BA
RST
Batch count
display mode
Remark 1) In the state of changing the preset value, if no button is pressed
for 60 seconds, it will automatically return to the running state, and the
setting data will not be saved.
CN7 SERIES COUNTER
3s/5s
3s