In the function of decimal point setting mode, select one digit after the
decimal point. (- - - - - - )
In the function of setting mode, use the left, down, and up keys
to set and set to 0.069.
This can adjust the position of the conveyor belt in 0.1mm units.
6. Menu Description
Setting Items
Setting content
Enter the preset menu password before entering the menu
setting state.If the password is wrong for 3 consecutive
times, it will automatically return to the measurement state
(initial password 0000)
Menu
Password
Input Mode
Counting
Speed
Output
Mode
Output
Delay Time
Min reset time
Input logic
Decimal point
Coefficient
value
Menu Password
Setting
Initial Value
Power
failure memory
If the output mode is S, T, D, the input mode can only
select Ud-A, B, C
※
Up or Down input mode
※
Up/Down - A
、
B
、
C input mode
Minimum RESET Signal Width
(
Unit:ms
)
:
NPN type sensor may have no voltage input.
Key Lock
Communica�on baud rate,Unit bps
Communication
subsequence
Transmission order of communication data in words
:
The key lock function is off, and
the LOCK light on the panel is off
Meter Address
RST button
:
change the demical point of coefficient value
* Set the counting value and demical point of the setting value.
Initial value: count value after manual or automatic reset.
:
:
OUT1 Output delay time setting
:
OUT2 Output
Software version
Software version for the counter meter
: Accumulate by batch, batch count value and
count value are displayed separately
: Accumulate by quantity, total count value and
count value are displayed separately
:Accumulate by batch, batch count value (upper
row) and count value (lower row) are displayed
at the same time
:Accumulate by total number, total count value
(upper row) and count value (lower row) are
displayed at the same time
Batch
accumulation
and display
mode
:None :Odd :Even
Menu password change (Please record the changed
password properly, otherwise you will not be able to enter
the setup menu)
Calibration
method
:
Count value reset a�er power off
:
Count value keeps a�er power off
The communication address of the counter can be set
arbitrarily between 1-247
MD
:
lock key,the LOCK light on.
RST
:
lock key, the LOCK light on.
RST
:
Press key,reset all menu
data to factory values
:
lock key, the LOCK light on.
PNP type sensor or no voltage input
Baud rate
menu (1 channel alarm product does not have this menu). Setting
range: 0.01s-499.99s (more than 499.99 will display "HOLD". At
this time, OUT1 will keep output for a long time until the reset
signal input or OUT2 delayed output ends.
delay time setting menu Setting range: 0.01s-499.99s
The counting speed indicates the maximum input
frequency allowed by INA and INB.
If it is set to 5K, the input signal frequency exceeds 5K
and the counting will be inaccurate.
9. Input logic diagram
2.Input mode
Input
mode
Counting Diagram
Counting value
Not counting
Not counting
Description
When INA is counting
input, INB stops
countinginput.
When INB is counting
input, INA stops
counting input.
Counting Value
Not Counting
Not coun�ng
When INA is counting
input, INB stops
counting input.
When INB is counting
input, INA stops
counting input.
Coun�ng Value
Counting input
Counting
instruction input
When INB ="L",
add “UP” to count
When INB ="H",
minus “DOWN”
to count
Coun�ng Value
If INA, INB change
from L to H at the
same time , then
maintain the
previous
count value.
Input count up
Input count down
Coun�ng value
When the A, B
inputphases of the
encoder are
connected to the
counter INA, INB,
please use the phase
difference input
(Ud-C) in the counter
input mode (in).
is above the minimum signal pulse width.
is more than 1/2 of the minimum signal pulse width,and if it is below this
signal pulse width, a count error of ± 1 will occur.
min signal pulse width.
Explaina�on of "H", "L" on the coun�ng chart
Input method
Voltage Input
Contactless input
Letter
Short circuit (Short)
Open circuit (Open)
Min signal pulse width
Counting Speed
Counting Speed Min signal pulse width
Minimum signal pulse width for each counting speed 1cps=1 Hz
One-shot Output (0.01-99.99s)
HOLD Output
One-shot Output
HOLD Output
Output at the
same time
Output
Mode
Input Mode
Description
After count-up, counting
display value increases
or decreases untill reset
signal is applied and
retained output is
maintained.
Output Mode