In the function of decimal point setting mode, select one digit after the 

decimal point. (- - - - - - )

In the function of setting mode, use                     the left, down, and up keys 

to set and set to 0.069. 

This can adjust the position of the conveyor belt in 0.1mm units.

6. Menu Description

Setting Items

Setting content

Enter the preset menu password before entering the menu 

setting state.If the password is wrong for 3 consecutive

times, it will automatically return to the measurement state 

(initial password 0000)

Menu

Password

Input Mode

Counting 

Speed

Output

Mode

  Output 

Delay Time

Min reset time

Input logic

Decimal point

Coefficient

 value

Menu Password 

Setting

Initial Value

Power 

failure memory

If the output mode is S, T, D, the input mode can only 

select Ud-A, B, C

Up or Down input mode

 

Up/Down - A

B

C input mode

 Minimum RESET Signal Width

Unit:ms

NPN type sensor may have no voltage input.

Key Lock

Communica�on baud rate,Unit bps

Communication

subsequence

Transmission order of communication data in words

:

The key lock function is off, and 

  the LOCK light on the panel is off

 Meter Address

 

RST button

change the demical point of coefficient value

* Set the counting value and demical point of the setting value.

Initial value: count value after manual or automatic reset.

OUT1 Output delay time setting

OUT2 Output 

Software version

Software version for the counter meter

: Accumulate by batch, batch count value and 

  count value are displayed separately

: Accumulate by quantity, total count value and 

  count value are displayed separately

:Accumulate by batch, batch count value (upper 

 row) and count value (lower row)  are displayed 

 at the same time

:Accumulate by total number, total count value 

(upper row) and count value (lower row) are

 displayed at the same time

Batch 

accumulation 

and display

mode

:None   :Odd    :Even

Menu password change (Please record the changed 

password properly, otherwise you will not be able to enter

the setup menu)

Calibration

method

Count value reset a�er power off

Count value keeps a�er power off

The communication address of the counter can be set 

arbitrarily between 1-247

MD

:

lock     key,the LOCK light on.

RST

:

lock             key, the LOCK light on.

RST 

:

Press       key,reset all menu

  data to factory values

:

lock             key, the LOCK light on.

PNP type sensor or no voltage input

Baud rate

menu (1 channel alarm product does not have this menu). Setting 

range: 0.01s-499.99s (more than 499.99 will display "HOLD". At 

this time, OUT1 will keep output for a long time until the reset 

signal input or OUT2 delayed output ends.

delay time setting menu Setting range: 0.01s-499.99s 

The counting speed indicates the maximum input 

frequency allowed by INA and INB. 

If it is set to 5K, the input signal frequency exceeds 5K 

and the counting will be inaccurate.

9. Input logic diagram

2.Input mode

Input 

mode

Counting Diagram

Counting value

Not counting

Not counting

Description

When INA is counting 

input, INB stops 

countinginput.

When INB is counting 

input, INA stops 

counting input.

Counting Value

Not Counting

Not coun�ng

When INA is counting

input, INB stops

 counting input.

When INB is counting 

input, INA stops 

counting input.

Coun�ng Value

Counting input

Counting

instruction input

When INB ="L",

add “UP” to count

 When INB ="H",

 minus “DOWN”

 to count

Coun�ng Value

If INA, INB change

from L to H at the 

same time , then

maintain the 

previous 

count value.

Input count up

Input count down

Coun�ng value

When the A, B 

inputphases of the 

encoder are 

connected to the 

counter INA, INB, 

please use the phase 

difference input 

(Ud-C) in the counter 

input mode (in).

is above the minimum signal pulse width.

is more than 1/2 of the minimum signal pulse width,and if it is below this

signal pulse width, a count error of ± 1 will occur.

min signal pulse width.

Explaina�on of "H", "L" on the coun�ng chart

Input method

Voltage Input

Contactless input

Letter

Short circuit (Short)

Open circuit (Open)

Min signal pulse width

Counting Speed

Counting Speed Min signal pulse width

Minimum signal pulse width for each counting speed   1cps=1 Hz

One-shot Output (0.01-99.99s)

HOLD Output

One-shot Output 

HOLD Output

Output at the 

same time

Output 

Mode

Input Mode

Description

After count-up, counting 

display value increases 

or decreases untill reset

signal is applied and

retained output is 

maintained.

Output Mode