6 "PRESS TO EXIT" BUTTON
6.1 Installation
It is possible to wire another button to be positioned next to the motorised door or door
equipped with an electric lock (internal side of the property). When this button is pressed,
the relay shall be actuated for the amount of time configured with switches 4 and 5 (see
5.1 Switch No. 28, page 9).
6.2 "Press to exit" button wiring
NC
VA
UX
+C
C
NO
GND
GND
PTE
BUS
BUS
GND
EB1
EB2
+V2
GND V
VID2
7 CONTROLLING AN ELECTRICAL LATCH
7.1 Installing a call memory latch
It is possible to control, via a one-touch control, an electrical call memory latch that
operates at 24 V (CA or CC), with no additional power supply.
The pulse supplied by the external module relay needs to be checked that it is
sufficent to activate the latch. If it is not, this latch should be used as model without
call memory, equipped with an external power supply and actuated by the external
module relay in "dry contact" mode.