background image

6

Copyright © 2015 Somfy SAS. All rights reserved.

EN

Images not contractually binding

2.3. COMMISSIONING 

Switch on the power supply.
If the motor is not set, the Led switches ON.
If the motor is already set, the Led Stay OFF.

WITH THE MOTOR HEAD BUTTONS

Press the 

Up 

and

 Down

 buttons on the motor head 

buttons  at  the  same  time:  The  motorised  product 

moves up and down.
The motor is in commissioning mode.

2.3.1. Checking the direction of rotation

1) Press the 

Up

 button on the motor head:

a) If the motorised product rises (a), the direction 

of  rotation  is  correct:  Move  onto  the  section 

entitled “Setting the end limits”.
b) If the motorised product lowers (b), the direction 

of rotation is incorrect: Move onto the next step.

2) Press the 

Stop

 button on the motor head until the 

motorised product moves up and down: The direction 

of rotation has been modified.

3) Press the 

Up 

button on the motor head to check 

the direction of rotation.

2.3.2. Setting the end limits

The end limits can be set in any order.

Setting the lower end limit

1) Press the 

Down

 button on motor head to lower 

the motorised product to the lower end limit.
2) Release the button to stop the motorised prod-

uct. If necessary, adjust the down position, using the 

Up

 or 

Down

 buttons.

3) Press the 

Up

 and 

Stop

 buttons at the same time 

until the motorised product moves.
The lower end limit is memorised. 

Setting the Upper end limit

1) Press the 

Up

 button on motor head to to raise the 

motorised product to the upper end limit.
2) Release the button to stop the motorised prod-

uct. If necessary, adjust the down position, using the 

Up

 or 

Down

 buttons.

3) Press the 

Down

 and 

Stop

 buttons at the same 

time until the motorised product moves.
The lower end limit is memorised. 

a

b

=

=

UP

ST

OP

DW
N

UP

ST

OP

DW
N

UP

ST

OP

DW
N

a

b

=

=

UP

ST

OP

DW
N

UP

ST

OP

DW
N

UP

ST

OP

DW
N

a

b

=

=

UP

ST

OP

DW
N

UP

ST

OP

DW
N

UP

ST

OP

DW
N

1)

2)

3)

1)

2)

3)

UP

ST

OP

DWN

UP

ST

OP

DWN

UP

ST

OP

DWN

UP

ST

OP

DWN

UP

ST

OP

DWN

UP

ST

OP

DWN

UP

ST

OP

DWN

UP

ST

OP

DWN

UP

ST

OP

DWN

UP

ST

OP

DWN

UP

ST

OP

DWN

UP

ST

OP

DWN

UP

ST

OP

DWN

UP

ST

OP

DWN

UP

ST

OP

DWN

UP

ST

OP

DWN

UP

ST

OP

DWN

UP

ST

OP

DWN

UP

ST

OP

DWN

UP

ST

OP

DWN

UP

ST

OP

DWN

UP

ST

OP

DWN

1)

2)

3)

UP

ST

OP

DWN

UP

ST

OP

DWN

UP

ST

OP

DWN

UP

ST

OP

DWN

UP

ST

OP

DWN

UP

ST

OP

DWN

UP

ST

OP

DWN

UP

ST

OP

DWN

UP

ST

OP

DWN

UP

ST

OP

DWN

UP

ST

OP

DWN

UP

ST

OP

DWN

UP

ST

OP

DWN

UP

ST

OP

DWN

UP

ST

OP

DWN

UP

ST

OP

DWN

UP

ST

OP

DWN

UP

ST

OP

DWN

UP

ST

OP

DWN

UP

ST

OP

DWN

UP

ST

OP

DWN

Summary of Contents for Sonesse Ultra 50 DC RS485

Page 1: ...Sonesse Ultra 50 DC RS485 Ref 5123104A EN Instructions ...

Page 2: ......

Page 3: ...A 50 DC motor is designed to operate multiple roller blinds simultaneously multi banding where these are interconnected by an intermediate bracket The Sonesse ULTRA 50 DC motor is not designed to be used with a compensating spring Any use outside the fields of application is prohibited in particular The Sonesse ULTRA50 DC motor is not designed for outdoor applications e g outdoor vertical blinds r...

Page 4: ...attached Safety instructions document after installing the motor Any After Sales Service operation on the motor must be performed by a motor and home automation professional If in doubt when installing the motor or to obtain additional information contact a Somfy adviser or go to the website www somfy com 2 INSTALLATION Instructions which must be followed by the motor and home automation professio...

Page 5: ...e the end cap into the roller tube and locked it if necessary 2 1 4 Installing the motor tube assembly The motorised product must not be compressed between the brackets 1 Install and fix the motor tube assembly onto the end bracket f and onto the motor bracket g Ensure that the motor tube assembly is secured onto the end bracket This operation prevents the motor tube assembly from coming out of th...

Page 6: ...t to the lower end limit 2 Release the button to stop the motorised prod uct If necessary adjust the down position using the Up or Down buttons 3 Press the Up and Stop buttons at the same time until the motorised product moves The lower end limit is memorised Setting the Upper end limit 1 Press the Up button on motor head to to raise the motorised product to the upper end limit 2 Release the butto...

Page 7: ...y The motor wheel and the crown are not suitable for the tube Replace the motor wheel and the crown The motorised product is com pressed between the brackets Increase the play between the brackets The tube contains swarf and screws Clean the roller tube During setting with the RS485 SET TING TOOL the following message error Not accepted by the node ap pears on the screen One step of the setting pr...

Page 8: ... UP STOP DWN UP STOP DWN UP STOP DWN UP STOP DWN UP STOP DWN UP STOP DWN UP STOP DWN UP STOP DWN UP STOP DWN UP STOP DWN UP STOP DWN UP STOP DWN UP STOP DWN UP STOP DWN UP STOP DWN UP STOP DWN UP STOP DWN UP STOP DWN UP STOP DWN UP STOP DWN UP STOP DWN UP STOP DWN UP STOP DWN UP STOP DWN UP STOP DWN UP STOP DWN 4 UP STOP DWN UP STOP DWN UP STOP DWN UP STOP DWN UP STOP DWN UP STOP DWN UP STOP DWN U...

Page 9: ...motor is in thermal protection mode Wait for the motor to cool down The motorised product realise a movement in the opposite direction of the last order The motorised product detect an obstacle Remove the obstacle 4 TECHNICAL DATA Power supply 24V dc Operating temperature 0 C to 60 C Index protection rating IP 20 Safety level Class III Manufacturer Model Ratings CUI INC E210311 EMSA240125 Input 10...

Page 10: ...leccione la posición predefinida 1 a 16 con los botones BACK OPEN STOP CLOSE OK LIGHT ZH 使用 BACK OPEN STOP CLOSE OK LIGHT 按钮选择预设位置 1至16 SOMFY RS485 NODE DISCOVERY NODE ID XXXXX BACK OPEN STOP CLOSE OK LIGHT BACK OPEN STOP CLOSE OK LIGHT BACK OPEN STOP CLOSE OK LIGHT BACK OPEN STOP CLOSE OK LIGHT MOTOR 50DC RS485 AP 0000000X0000 ST 0000000A0000 BACK OPEN STOP CLOSE OK LIGHT BACK OPEN STOP CLOSE OK ...

Page 11: ...VERSED OK TO CONFIRM UP SPEED SETTING BACK OPEN STOP CLOSE OK LIGHT BACK OPEN STOP CLOSE OK LIGHT DOWN SPEED SETTING XXX BACK OPEN STOP CLOSE OK LIGHT BACK OPEN STOP CLOSE OK LIGHT UP SPEED SETTING XXX DOWN SPEED SETTING XXX BACK OPEN STOP CLOSE OK LIGHT BACK OPEN STOP CLOSE OK LIGHT BACK OPEN STOP CLOSE OK LIGHT BACK OPEN STOP CLOSE OK LIGHT BACK OPEN STOP CLOSE OK LIGHT SLOW SPEED SETTING XXX BA...

Page 12: ...leccione la posición predefinida 1 a 16 con los botones BACK OPEN STOP CLOSE OK LIGHT ZH 使用 BACK OPEN STOP CLOSE OK LIGHT 按钮选择预设位置 1至16 SOMFY RS485 NODE DISCOVERY NODE ID XXXXX BACK OPEN STOP CLOSE OK LIGHT BACK OPEN STOP CLOSE OK LIGHT BACK OPEN STOP CLOSE OK LIGHT BACK OPEN STOP CLOSE OK LIGHT MOTOR 50DC RS485 AP 0000000X0000 ST 0000000A0000 BACK OPEN STOP CLOSE OK LIGHT BACK OPEN STOP CLOSE OK ...

Page 13: ... CLOSE OK LIGHT BACK OPEN STOP CLOSE OK LIGHT BACK OPEN STOP CLOSE OK LIGHT BACK OPEN STOP CLOSE OK LIGHT BACK OPEN STOP CLOSE OK LIGHT BACK OPEN STOP CLOSE OK LIGHT BACK OPEN STOP CLOSE OK LIGHT BACK OPEN STOP CLOSE OK LIGHT SET OVERTORQUE PROTECTION SET OVERTORQUE PROTECTION H SET OVERTORQUE PROTECTION L BACK OPEN STOP CLOSE OK LIGHT BACK OPEN STOP CLOSE OK LIGHT BACK OPEN STOP CLOSE OK LIGHT BA...

Page 14: ...14 Copyright 2015 Somfy SAS All rights reserved EN Images not contractually binding ...

Page 15: ...15 Copyright 2015 Somfy SAS All rights reserved EN Images not contractually binding ...

Page 16: ...www somfy com Somfy SAS 50 avenue du Nouveau Monde F 74300 CLUSES Somfy SAS capital 20 000 000 Euros RCS Annecy 303 970 230 09 2015 ...

Reviews: