ADDITIONAL PROGRAMMING INSTRUCTIONS

MOTOR COMPATIBILITY

ORDERING INFORMATION

A.  RTS Transmitter

B.  SDN Addressees

PROGRAMMING ADDITIONAL RTS TRANSMITTERS: 

 Press and hold the programming button of a Telis Transmitter previ-

ously memorized by the RTS Receiver until the LED on the receiver turns on. Press and release the programming button on 
the new transmitter or channel. The LED on the receiver will turn off, indicating this transmitter has been memorized. Repeat 
this procedure for each transmitter or channel, up to 5 total.

DELETING AN RTS TRANSMITTER FROM MEMORY:  

Press and hold the programming button of a Telis Transmitter pre-

viously memorized by the RTS Receiver, but not the one to be removed from memory. Continue holding the button until the 
LED on the receiver turns on. Press and release the programming button on the transmitter or channel to be removed from 
memory. The LED on the receiver will turn off, and that transmitter will no longer operate the RTS receiver.

CHANGING SDN GROUP ADDRESSES: 

 Connect the RTS Receiver to a computer running the Somfy configuration software. 

Select correct com port, then click on connect. Enter the RTS Receiver address next to “Get MTR Addr”. Click on Single then 
“Get Group Addr”. New addresses can be entered in positions 1 - 5. Click on “Set” to confirm.

REMOVING ALL RTS TRANSMITTERS and GROUP ADDRESSES: 

Press and release the reset button on the RTS Receiver. 

The LED will turn on, indicating that no transmitters or group addresses are memorized.

The RTS Receiver for SDN is compatible with the following motors:

NOTE: Systems that include the Sonesse 50 ILT or the LT50 ILT series motors should not use this product. Please use RTS Receiver 

(for Legacy ILT Motors) Part #1822541.
Systems that include the animeo IP Building Controller should not use this product. Please use RTS Receiver for animeo IP 

Part #1822447.

Sonesse

®

 50 RS485 (AC)

Sonesse

®

 50 RS485 (DC)

LT50 RS485 (AC)
Sonesse

®

 30 RS485 (DC)

RTS Receiver for SDN
USB to RS485
Bus Power Supply

1822294
9015260
1822440

DESCRIPTION

PART NUMBER

Reviews: