EN
Rollixo Smart io
42
Copyright
©
2020 SOMFY ACTIVITES SA. All rights reserved.
11 DIAGNOSTIC AND TROUBLESHOOTING
11.1 Indicator light status
Off
Slow flashing
Permanently lit
Rapid flashing
Very rapid flashing
11.2 Diagnostic
POWER indicator
Electronic in motor setting mode
→ If necessary, check the direction of rotation of the motor and adjust the motor end limits.
Product adjusted
Motor thermal cut-out
→ Switch the power supply off, wait about 5 min. then switch the power supply back on.
Photoelectric cells indicator light
Normal operation
• Detection in progress
→ Once detection is complete, the indicator light goes out.
• Permanent fault
→ Check the alignment and wiring of the cells.
NOTICE! After 3 mins, the wired control input (terminals 20 and 21) allows the door to be
controlled in dead-man mode.
Auto-test in progress
→ Once the auto-test is complete, the indicator light goes out.
Safety edge indicator light
• Normal operation
• If the safety edge is not activated when the door encounters an obstacle when closing,
the direction of rotation of the motor must be checked.
• Detection in progress
→ Once detection is complete, the indicator light goes out.
• Permanent fault
→ Check the safety edge wiring.
NOTICE! After 3 mins, the wired control input (terminals 20 and 21) allows the door to be
controlled in dead-man mode.
Auto-test in progress
→ Once the auto-test is complete, the indicator light goes out.
Fall protection indicator light
Normal operation