LEVIXO 30/50 230V RTS
EN
9
Copyright
©
2017 SOMFY ACTIVITES SA. All rights reserved.
8. PROGRAMMING THE REMOTE CON-
TROLS
8.1. Memorising 2- or 4-button remote controls to
control the auxiliary output - Fig. 31
1) Press the PROG button for 2 s.
The red indicator will come on permanently.
2) Press the PROG button a second time.
The red indicator light flashes once slowly for 0.5 seconds.
3) Press the PROG button a third time.
The red indicator light flashes once very slowly for 2 seconds.
4) Press the button on the remote control to control the auxiliary output.
The red indicator light flashes; the remote control has been memo-
rised.
8.2. Clearing the remote controls - Fig. 32
Press the PROG button on the control unit for 7 seconds.
9. TROUBLESHOOTING THE SAFETY EDGE
1) Switch dipswitch no.10 to OFF.
2) Disconnect the safety edge and create a bridge between terminals 14
and 15 of the motor electronics.
Danger
The motorisation is operating with no safety device.
Once troubleshooting has been carried out:
3) Remove the bridge between terminals 14 and 15 of the motor’s elec-
tronics.
4) Switch dipswitch no.10 to ON.
5) Test the safety edge.
10. TECHNICAL DATA
Barrier
Power supply
220-230 Vac 50/60 Hz
Power consumption
300 W
Maximum torque
85 Nm (Levixo 30) / 250 Nm (Levixo 50)
End limits
Integrated and adjustable electrical
Obstacle detection
Safety edge active with autotest
Unlocking
Individual key
Opening time
4 s (Levixo 30) / 8 s (Levixo 50)
Maximum boom length
3 m without accessories (Levixo 30) /
5 m without accessories (Levixo 50)
Climatic operating conditions
- 20°C/+ 60°C - IP 44
Use - maximum number of
cycles
Semi-intensive - 960 cycles/day for
Levixo 30 - 600 cycles/day for Levixo 50
Weight (without boom)
35.6 kg
Control unit
Somfy radio frequency
433.42 MHz
< 10 mW
Number of channels that can
be memorised
128
Safety input
configur-
able during
closing
Type
Dry contact: NC
Compatibility
TX/RX photoelectric cells - Reflex cell -
Safety edge
Wired control input
Dry contact: NO
Orange light output
220/230 V - 50/60- 60 Hz
Safety input tests output
Yes: for possible autotest for cell active
during closing and safety edge
Accessories power supply
output
24 Vac - 315 mA max
Offset aerial input
Yes: compatible with RTS aerial
(ref. 2400472)
Automatic closure mode
Yes: re-closure time-out programmable
from 0 s to 120 s
Orange light warning
Programmable: without or without
warning (fixed duration of 2 s)