Copyright 2013 Delta Scientific Corporation 

Page 1 of 17 

All Rights Reserved 

Document A2021.6 

INSTRUCTION MANUAL 

MODEL AG812 ACCESS GATE 

 

 

WARRANTY 

 

INSTALLATION 

 

OPERATION 

 

 

 

 

 

 

 

 

 

 

 

CORPORATE HEADQUARTERS 

40355 Delta Lane 
Palmdale, California 93551 
Phone:  (661) 575-1100 
Fax:      (661) 575-1109 
Email:  [email protected] 

EASTERN REGION U.S.A. 

125 Wyatt Lane 
Fredericksburg, VA 22406 
Phone:  (540) 310-4050 
Fax:      (540) 310-4157 
Email:  [email protected] 

Summary of Contents for AG812

Page 1: ...ODEL AG812 ACCESS GATE WARRANTY INSTALLATION OPERATION CORPORATE HEADQUARTERS 40355 Delta Lane Palmdale California 93551 Phone 661 575 1100 Fax 661 575 1109 Email info deltascientific com EASTERN REGI...

Page 2: ...ISCLAIMER Please note careful consideration must be devoted to the selection placement and design of a Barricade installation Just as in the case of any Barricade system perimeter security device or s...

Page 3: ...MANUAL GATE ARM OPERATION OPTION 6 DRIVE BELT TENSION 6 SPARE PARTS ORDER DATA 7 DART ARM OPTION 7 HOOK UP SCHEMATICS 2 Lane Single Direction Cash In Or Out 8 2 Lane Cash Entry Free Exit 9 1 Lane Coi...

Page 4: ...These devices may be used independently or in combination In short any device which can provide a contact closure may be used to vend or reset the Gate Safety The Model AG812 Access Gate is equipped w...

Page 5: ...ox breather vent and remove plug Vent hole faces upwards when the box is in operation 8 Install Gate Arm Wiring As indicated above the Gate will function using a wide variety of control inputs Consult...

Page 6: ...loosen the thumbscrew on the up limit switch cam and rotate slightly CCW Confirm as above 4 To adjust the gate arm for less upward travel loosen the thumbscrew on the up limit switch cam and rotate s...

Page 7: ...c For control circuits list model number serial number S N drawing number and customer number taken from the nameplate on the controller Dart Arm optional The dart arm is an optional factory installed...

Page 8: ...Copyright 2013 Delta Scientific Corporation Page 8 of 17 All Rights Reserved Document A2021 6...

Page 9: ...Copyright 2013 Delta Scientific Corporation Page 9 of 17 All Rights Reserved Document A2021 6...

Page 10: ...Copyright 2013 Delta Scientific Corporation Page 10 of 17 All Rights Reserved Document A2021 6...

Page 11: ...Copyright 2013 Delta Scientific Corporation Page 11 of 17 All Rights Reserved Document A2021 6...

Page 12: ...Copyright 2013 Delta Scientific Corporation Page 12 of 17 All Rights Reserved Document A2021 6...

Page 13: ...Copyright 2013 Delta Scientific Corporation Page 13 of 17 All Rights Reserved Document A2021 6...

Page 14: ...Copyright 2013 Delta Scientific Corporation Page 14 of 17 All Rights Reserved Document A2021 6...

Page 15: ...ly by draining old oil and refilling with clean Texaco Vanguard oil or equivalent 2 Tighten all nuts bolts and screws on the Gate assembly every 60 days or as necessary 3 Wash and wax the Gate cabinet...

Page 16: ...e belt tension to be checked Open the AG812 s door and inspect the drive belt for looseness or excessive wear If the belt appears worn or frayed or if the belt appears loose first remove Electrical Po...

Page 17: ...T ASSEMBLY 4369 11 BEARING PLATE with BUSHING FOR AG812 4369 12 SHAFT COLLAR 1 25 BORE 4369 13 ARM HOLDER 4369 14 ARM HOLDER RETAINING PLATE 4369 15 CONNECTING ARM with BUSHING 4369 16 GEAR BOX MOUNTI...

Page 18: ......

Page 19: ...PLATE 4369 14 15 1 CONNECTING ARM WITH BUSHINGS 4369 15 15A 1 DART CONNECTING ARM ASSY OPTION 5 7 5 7 3312 00 16 1 GEAR BOX MOUNTING PLATE 4369 16 17 1 MOTOR MOUNTING PLATE 4369 17 18 2 LIMIT SWITCH...

Page 20: ...F MALE CTB 7300 24F L CAMDEN TERMINAL STRIP FEMALE CTB 7300 12F MALE CTB 7300 12F STAT THERMOSTAT PEPI MODEL C 24 B1 BRIDGE DIODE 1A 50V DIGI KEY DB 101NP C1 CAPACITOR 1000 mF 35V C2 CAPACITOR 330 mF...

Page 21: ......

Page 22: ...R 330 OHM 1 2W U1 U2 OPTO ISOLATOR MOTOROLA MOC3041 CA CAMDEN TERMINAL STRIP FEMALE CTB 7300 24F MALE CTB 7300 24F L CAMDEN TERMINAL STRIP FEMALE CTB 7300 12F MALE CTB 7300 12F STAT THERMOSTAT PEPI MO...

Page 23: ......