3 x 0,75 mm

2

IB BUS line

3 x 0,75 mm

2

IB BUS line

3 x 0,75 mm

2

IB BUS line

CENTRALIS IB

CENTRALIS UNO IB VB

CENTRALIS UNO IB VB

MAINS

230V - 50Hz

3 wires x 1,5 mm

2

3 wires x 0,75 mm

2

3 wires x 0,75 mm

2

5 wires x 1,5 mm

2

5 wires x 1,5 mm

2

4 wires x 0,75 mm

2

4 wires x 0,75 mm

2

Neutral

Earth

Phase

MAINS

230V - 50Hz

3 wires x 1,5 mm

2

Neutral

Earth

Phase

+

N

L
N

+

+

-

C

1

2

345

6

N

L
N

1

2

345

6

Centralis uno IB VB

Junction box

Motor

Supply

Phase

Neutral

Earth

Earth 

(green/yellow)

Common 

(blue)

Up 

(black or brown)

Down 

(black or brown)

L

N

N

+

Centralis IB

C

1

2

3

4

5

6

CABLING OF SEVERAL CONTROL POINTS FOR SEVERAL BLINDS

CENTRALIS uno IB 

VB with CENTRALIS IB

®

Set the switch of the CENTRALIS IB

on the “+” position.

Summary of Contents for inteo CENTRALIS UNO IB VB

Page 1: ...arate the cables for the BUS line and the cables for the power supply Main supply 220 240V 50Hz Class II product Protection index IP40 Output 250V 3A cosφ 0 8 Output temporisation momentary or fixed activ for 180s Environmental conditions for use temperature 5 C to 40 C no condensation allowed pollution degree typical for usual living space EN60730 1 EN50081 1 EN50082 1 Installation allowed only b...

Page 2: ...wice The CENTRALIS uno IB VB has three keys to control the blind individually and has also a BUS line input to connect a master control with a CENTRALIS IB see page 4 EU mode To raise or lower the blind press and hold 2 sec the correspondings keys or To tilt the slats press briefly the correspondings keys or To stop the blind press the stop key US mode To raise or lower the blind press briefly the...

Page 3: ...set from the UP limit of the venetian blind in order to always get the same adjust ment Non binding document Products and references in this document are subject to change without prior notice Please consult SOMFY before using such references SOMFY 09 00 To reach the right intermediate position preset the blind must be at its UP limit Press briefly the key The blind moves down stops at the interme...

Page 4: ...x 0 75 mm 2 4 wires x 0 75 mm 2 Neutral Earth Phase MAINS 230V 50Hz 3 wires x 1 5 mm 2 Neutral Earth Phase N L N C 1 2 3 4 5 6 N L N 1 2 3 4 5 6 Centralis uno IB VB Junction box Motor Supply Phase Neutral Earth Earth green yellow Common blue Up black or brown Down black or brown L N N Centralis IB C 1 2 3 4 5 6 CABLING OF SEVERAL CONTROL POINTS FOR SEVERAL BLINDS CENTRALIS uno IB VB with CENTRALIS...

Reviews: