2.3.1. Setting the end limits
1) Switch on the power supply.
2) A[er the first
Open
or
Close
command, the motorised product will run at reduced speed to one end, then
the other, to set the End Stops.
2.3.2. Checking the direction of rotation (Fig E)
Move the curtain away from the end limits.
1) Press the
Open
button on the control point:
a) If the motorised product opens (a), the direction of rotation is correct.
b) If the motorised product closes (b), the direction of rotation is incorrect: Move onto the next step.
2) Press the
Open
,
Stop
and
Close
buttons simultaneously until the motorised product moves
3) Press the
Stop
button until the motorised product moves, to reverse the rotation direction.
4) Press the
Open
button on the control point to check the direction of rotation.
2.3.3. Adjusting the Touch motion sensitivity (Fig F)
1) Press the
Open
,
Stop
and
Close
buttons of the control point simultaneously until the motorised product moves.
2) Press the
Open
and
Close
buttons simultaneously until the motorised product moves to switch from high sensitivity,
to low sensitivity, to no touch motion, and back to high sensitivity.
3) Press the
Stop
button until the motorised product moves to confirm the setting.
2.3.4. SILENT or HI-SPEED mode (Fig G)
On the motor you can switch from the silent mode to the Hi-speed mode by sliding the “selector” from SILENT to
Hi-SPEED.
In silent mode, the motor speed is 7.5cm/s. And in hi speed mode, the speed can be adjustable, refer 2.3.5
for details.
2.3.5. Adjusting the HI-SPEED (Fig H)
1) Press the
Open
and
Stop
buttons simultaneously until the motorised product moves.
2) Press the
Open
button to increase the speed, and the
Close
button to decrease the speed.
There are 4 speed options: 12.5 cm/s - 15 cm/s (default speed) - 17.5 cm/s - 20 cm/s.
3) Press the
Stop
button until the motorised product moves to confirm the setting.
2.3.6. Dry contact ergonomics setting : Standard or 2 buttons sequencing (Fig I)
1) Press the
Open
,
Stop
and
Close
buttons of the control point simultaneously until the motorised product moves.
2) Press the
Stop
and
Close
buttons of the control point simultaneously until the motorised product moves to change
the ergonomics.
2.4. TIPS AND RECOMMENDATIONS FOR INSTALLATION
2.4.1. Questions about the Glydea Ultra?
Observations
Possible causes
Solutions
The motorised product does
not operate.
The wiring is incorrect.
Check and reconnect the power supply
The control point is not
compatible.
Check for compatibility and replace the
control point if necessary.
2.4.2. Re-setting the end limits
Readjusting the Open end limit (Fig J)
1) Press the
Open
button to move the motorised product to the end limit to be readjusted.
2) Press the
Open
,
Stop
and
Close
buttons of the control point simultaneously until the motorised product moves.
3) Press the
Open
or
Close
button to move the motorised product to the new desired position.
4) To confirm the new end limit, press the
Stop
button until the motorised product moves.
Readjusting the Close end limit (Fig K)
1) Press the
Close
button to move the motorised product to the end limit to be readjusted.
2) Press the
Open
,
Stop
and
Close
buttons of the control point simultaneously until the motorised product moves.
3) Press the
Open
or
Close
button to move the motorised product to the new desired position.
4) To confirm the new end limit, press the
Stop
button until the motorised product moves.
2.4.3. Erasing the memory of the motor (Fig L)
Press and hold the
Open
,
Stop
and
Close
buttons simultaneously until the motorised product moves 3 times.
All the settings are erased.