2.3.1. Setting the end limits 
1) Switch on the power supply. 

2) A[er the first 

Open

 or 

Close 

command, the motorised product will run at reduced speed to one end, then 

the other, to set the End Stops. 

2.3.2. Checking the direction of rotation (Fig E)

Move the curtain away from the end limits.
1) Press the 

Open

 button on the control point:

a) If the motorised product opens (a), the direction of rotation is correct.
b) If the motorised product closes (b), the direction of rotation is incorrect: Move onto the next step.

2) Press the 

Open

 , 

Stop 

and 

Close 

buttons simultaneously until the motorised product moves

3) Press the 

Stop

 button until the motorised product moves, to reverse the rotation direction.

4) Press the 

Open

 button on the control point to check the direction of rotation.

2.3.3. Adjusting the Touch motion sensitivity (Fig F)

1) Press the 

Open

Stop 

and 

Close

 buttons of the control point simultaneously until the motorised product moves.

2) Press the 

Open

 and 

Close

 buttons simultaneously until the motorised product moves to switch from high sensitivity, 

to low sensitivity, to no touch motion, and back to high sensitivity.
3) Press the 

Stop 

button until the motorised product moves to confirm the setting.

2.3.4. SILENT or  HI-SPEED mode (Fig G)

On the motor you can switch from the silent mode to the Hi-speed mode by sliding the “selector” from SILENT to 
Hi-SPEED.

 

In silent mode, the motor speed is 7.5cm/s. And in hi speed mode, the speed can be adjustable, refer 2.3.5 

for details.

2.3.5. Adjusting the HI-SPEED (Fig H)

1) Press the 

Open

 and 

Stop

 buttons simultaneously until the motorised product moves.

2) Press the 

Open

 button to increase the speed, and the 

Close

 button to decrease the speed. 

There are 4 speed options: 12.5 cm/s - 15 cm/s (default speed) - 17.5 cm/s - 20 cm/s.
3) Press the 

Stop

 button until the motorised product moves to confirm the setting.

2.3.6. Dry contact ergonomics setting : Standard or 2 buttons sequencing (Fig I)

1) Press the 

Open

,

Stop

 and 

Close

 buttons of the control point simultaneously until the motorised product moves.

2) Press the 

Stop

 and 

Close

 buttons of the control point simultaneously until the motorised product moves to change 

the ergonomics.

2.4. TIPS AND RECOMMENDATIONS FOR INSTALLATION

2.4.1. Questions about the Glydea Ultra?

Observations

Possible causes

Solutions

The motorised product does 
not operate.

The wiring is incorrect. 

Check and reconnect the power supply

The control point is not 
compatible.

Check for compatibility and replace the 
control point if necessary.

2.4.2. Re-setting the end limits
Readjusting the Open end limit (Fig J)

1) Press the 

Open

 button to move the motorised product to the end limit to be readjusted.

2) Press the 

Open

Stop 

and 

Close

 buttons of the control point simultaneously until the motorised product moves.

3) Press the 

Open

 or 

Close 

button to move the motorised product to the new desired position.

4) To confirm the new end limit, press the 

Stop

 button until the motorised product moves.

Readjusting the Close end limit (Fig K)

1) Press the 

Close

 button to move the motorised product to the end limit to be readjusted.

2) Press the 

Open

Stop 

and 

Close

 buttons of the control point simultaneously until the motorised product moves.

3) Press the 

Open

 or 

Close 

button to move the motorised product to the new desired position.

4) To confirm the new end limit, press the 

Stop

 button until the motorised product moves.

2.4.3. Erasing the memory of the motor (Fig L)

Press and hold the 

Open

Stop 

and 

Close

 buttons simultaneously until the motorised product moves 3 times.

All the settings are erased.