2. INSTALLATION

Instructions which 

 must

 be followed by the drive and home automation professional installing the Glydea 

Ultra motor.
Never drop, knock, drill or submerge the drive.
Install a separate control point for each drive.

2.2. WIRING 

(Fig C)

Cables which pass through a metal wall must be protected and isolated using a sheath or sleeve.
Attach cables to prevent any contact with moving parts.

Leave the drive power supply cable accessible: it must be possible to replace it easily.

 

-

Switch off the power supply.

 

-

Connect the drive according to the information in the table below:

AC wiring 

(Fig C1)

DCT wiring 

(Fig C2)

Drives equipped with a US power plug

 (Fig C3)

Compatible controls - Wiring of control 

(Fig D)

1) Setting tool
2) Centralis IB
3) 2 NO (Normally Open) Dry contact switch

2.3. COMMISSIONING

2.1. INSTALLATION 

2.1.1. Installation of the rail (Fig A)

1) Mark the position of the brackets.
2) Drill the ceiling or the wall at the right places.
3) Attach the brackets.
4) Attach the rail on the brackets.

2.1.2. Installation of the motor (Fig B)

1) Unlock the motor 
2) Insert the motor sha[ into the drive pulley hole.
3) Lock the motor.

1

CCW (Open) NO Dry contact

4

2

5

Stop - NO Dry contact

3

Ground Common

6

CW (Close) NO Dry contact

Wire

100V to 240V 

1

Neutral

Blue

2

Live

Brown

3

Earth

Yellow / Green

Open

Stop

Close