13
Installation
1
EN
EN
- FREEVIA LINE installation and operating guide - SOMFY
1.6 Connecting to the 230V power supply
•
For your safety, these operations must be
carried out with the power supply switched off.
•
Use a 3 x 1.5 mm² cable or 3 x 2.5 mm² for
outdoor use (type H07RN-F minimum).
•
The cable clamp supplied must be used.
For all low-voltage cables, ensure that
they can withstand traction of 100 N.
Check that the conductors have not moved
when this traction has been applied.
Neutral
150 mm
8 mm
100 mm
Live
1.
Strip the wire over a distance of
150 mm.
2.
Overlap the live and neutral wires
at 100 mm.
3.
Strip the 3 wires over a distance of
8 mm.
4.
Crimp the terminal provided
on the earth wire (yellow and
green).
6.
Connect the wires as shown in the
table:
Wire
colour
Type
Terminal Comments
Blue
Neutral
17
Brown /
black / red
Live
16
Yellow and
green
Earth
Tighten a flat
washer
,
the
power supply earth
terminal crimped
in step 4 and a star
washer
using a
screw
.
7.
Tighten the cable clamp supplied.
For a 3x1.5 mm² cable
For a 3x2.5 mm² cable
A
N
T
AN
T
BUSBUS
11
33
22
44
55
66
S
TAR
T
ART
M1M1
M
2
M2
1111
1
3
1
3
1
0
1
01
2
12
BA
TT
BA
TT
++
--
LI
G
HT
LI
GHT
2
30
V
2
30
V
1515
1717
1414
1
6
1
6
77
-
F
LA
S
H
88
99
2
4V
+
LL
NN
16
17
230V
Neutral
Live