Dexxo Pro RTS
Copyright © 2015 Somfy SAS. All rights reserved
5
en
remote lighting operation
Remote lighting operation
The light comes on every time the motor drive unit is operated. The light will go
out one minute after the door stops moving. The time delay can be adjusted
during installation.
If a remote control button is programmed for remote lighting, it works as
illustrated as below.
automatic closure mode operation
The door is automatically closed after a time delay set at the time of installation.
An additional command during this time will cancel the automatic closure and
the door will remain open.
Working from the back-up battery - ref.9001001
If a back-up battery is installed, the Dexxo Pro motor will operate when a power
cut occurs.
The following conditions apply to operation:
-Door speed is reduced.
-The light will not come on.
-The safety devices are disabled.
Battery specifications:
- Endurance: The battery will last for 24 hours with a maximum of 5 to 10
operating cycles depending on the weight of the door.
-Recharging time: 48 hours.
-Service life prior to replacement: approx. three years.
To ensure optimum battery life, we recommend that the power to the motor is
switched off and the door is operated for a number of cycles using
battery power (three times a year).
Forced operation mode
This function makes it possible to manipulate the door at any moment (loss of
remote control, photoelectric cell fault, etc.).
Remove the integrated light cover to access the “+” and “-” buttons.
Door stationary:
press the “-” button to close it
press the “+” button to open it.
Door moving: press the “-” or “+” button to stop the door.
Detection of forced entry operation
Detection of forced entry starts operating 30 seconds after the door is closed.
If forced entry is detected, the siren will sound for 2 minutes, the light integrated
in the motor and the orange light (if installed) will flash. To stop the siren, press
a button on a memorised remote control.
4.3
Adding a remote control without accessing the
motor head
With a Keygo
2s
B
A
A
with a telis or similar
A
B
2s
< 1s
5 - troUBlesHootinG
5.1
Digital display
The LCD display is situated under the lighting cover. It provides motor operation
status.
The main operating codes are as follows:
Code
description
Comments
Waiting for a command
Door opening
Waiting for the door to
close
Door closing
Obstacle detection
Indicates that the door encountered an
obstacle. The display is maintained for
30 s after detection.
Safety input active
Indicates that an obstacle preventing
door closure is present between the
photoelectric cells or is in contact with
the safety sensor bar installed on the
door.
Pedestrian door safety
contact active
Indicates that the pedestrian door within
the garage door is open. Door operation
is inhibited.
Permanent hardwired
control
Indicates that the hardwired control input
is permanently active. Commands from
radio remote control units are inhibited.
Maintenance is required Indicates that maintenance is required on
the installation. Contact your installer.
Working from back-up
battery
Waiting for a command
Indicates that the main power supply
to the motor is cut and that the motoris
powered by the battery backup pack.
/
Detection of forced entry Indicates that an attempt to open the garage
door has been made from outside.
Press a button on the memorised remote
control to stop the siren.
Start a complete opening and closing cycle.
If other codes are displayed, contact your Somfy installer.
5.2
Power outage
Following a power outage, the motor must recognise its «fully open» position
again.
Open the door fully using a memorised remote control. The door will open at a
degraded speed.
Allow the door to open to the «fully open» position.