Page 2: ...ly Open Contacts Normally Closed Contacts Gatekeeper Status What do the lights mean Troubleshooting Gatekeeper s Power Button is not turning on Gatekeeper s Ser1 Ser2 light s are not turning on Door R...

Page 3: ...may be supplied with Desktop card reader regular USB data cable Wall mounted card reader with Diode You will also need the following items Battery and power supply Router or network switch Internet co...

Page 4: ...atekeeper and Card Reader to optimize the full benefits of the Gatekeeper as well as for security in the event of power failure It is necessary that an Emergency Fire Exit Button be included in your d...

Page 5: ...are often inductive switching off the current can cause a voltage spike on the wires to the access control damaging the reader A snubber should be fitted near any switch or relay contacts for DC circ...

Page 6: ...Screw Terminals Some readers have screw terminals instead of wires Use the following key to interpret the diagrams All other terminals are not used Terminal Wire Colour VCC Red GND Black A Green B Whi...

Page 7: ...and fail safe electronic locks are as follows Fail secure locks will lock the door when the power goes off whereas Fail safe locks will leave the door unlocked when the power goes off Fail Secure EPIC...

Page 8: ...rgency Exit EPIC Sanctuary 78 106 Manchester St Christchurch 8011 New Zealand PO Box 13352 Armagh Mail Centre Christchurch 8011 New Zealand www gymmastersoftware com NZ 03 974 9169 AU 03 9111 0323 US...

Page 9: ...EPIC Sanctuary 78 106 Manchester St Christchurch 8011 New Zealand PO Box 13352 Armagh Mail Centre Christchurch 8011 New Zealand www gymmastersoftware com NZ 03 974 9169 AU 03 9111 0323 US 415 678 127...

Page 10: ...gency Exit EPIC Sanctuary 78 106 Manchester St Christchurch 8011 New Zealand PO Box 13352 Armagh Mail Centre Christchurch 8011 New Zealand www gymmastersoftware com NZ 03 974 9169 AU 03 9111 0323 US 4...

Page 11: ...haring wiring pattern above The wiring pattern you should use depends on which relay contacts are being used Normally Open Contacts In arrangements where the normally open NO contacts are used wire th...

Page 12: ...er to the Gatekeeper unit 4 Error Red Off There is an error 5 Reader 1 Reader 2 On Off Reader s are connected 6 Database On Off Connection to the cloud server 7 Internet On Off Internet Connection 8 A...

Page 13: ...es an electrical fault It could be 1 A wiring fault short circuit somewhere on the card reader cable 2 Something on the card reader cable is consuming too much power 3 a bad power supply 4 a faulty Ga...

Page 14: ...from green to red If this does not happen then it would be due to the following causes Faulty tag Faulty reader Faulty cable Door has been disconnected from the Gatekeeper Tag has not been activated i...

Page 15: ...ix Incorrect wiring to door lock or relay Faulty relay Note on Power Supply The power supply must provide 12V DC It is recommended that an uninterruptible power supply UPS is used to back it up EPIC S...