/ Sensor status
Sun 1:
12
klx
Sun 2:
12
klx
Wind 1:
12
m/s
Wind 2:
12
m/s
/ Error
Reset error list…
Sun 1: Not connected
Temperature: Short circuit
8
M. chEck SEnSorS
Go to
Sensors status
. Wind and sun sensors
should normally show a value higher then zero.
If that is the case, then everything is fine. If it’s
very dark use a flashlight on the sun sensor to
simulate sun and check the value. If there’s
no wind just turn the windmill manually and
check the value. If you have more then one
sun and/or wind sensor make sure that the
corresponding sensor is connected to the correct input. The easiest way of doing this is to
cover one sensor and then check the value/s.
n. ErrorS
Check
Error list
if any errors.
If yes, consult the owners manual.
o. SEttingS
The settings depend on the functions to be used. For detailed information, please see the
owner’s manual.
The minimum settings are listed below:
l
Disable functions that are not to be used. Especially important for wind, sun and heat
functions as they will generate errors if the referring sensor is not connected.
l
Sensor allocation for wind and sun, if more then one sun and/or wind sensor are used.
l
Wind threshold. For exact values please contact the solar protection supplier.
The table below is for guidance only:
l
If Alarm function is to be used, enable function.
Type
Wind Speed
m/s
km/h
Mph
Façade awning / Screen
10
36
22
External Venetian blind
15
54
33
Folding arm awning
8
28
18
UK