2. 2. WIRING
!
Cables which pass through a metal wall must be protected and insulated using a sheath or sleeve.
!
Attach cables to prevent any contact with moving parts.
!
If the drive is used outdoors and if the power supply cable is of the H05-VVF type, route the cable in
a UV-resistant duct, e.g. trunking.
!
The drive cable can be removed. If it becomes damaged, replace it with an identical cable.
1
Leave the drive power supply cable accessible: it must be easily replaceable.
1
Always make a loop in the power supply cable to prevent water entering the drive!
1)
Switch o
ff
the power supply.
2)
Connect the drive according to the information in the table
below:
Cable
Neutral (N)
Live (L)
Earth ( )
230 V
50 Hz
Blue
Brown
Green/yellow
2. 3. COMMISSIONING
These instructions describe commissioning the drive using a local Somfy io-homecontrol
®
control point.
A local Somfy io-homecontrol
®
control point is a one-way radio transmitter .
2. 3. 1. Identifying the commissioning steps already completed
1
Only one drive should be supplied at a time.
Three di
ff
erent reactions can be used to identify the status of the drive. Cut the power supply to a single
motorised product for two seconds to ascertain the status of the drive:
Reaction 1:
When switched on, the motorised product moves up and down.
-
The travel end limits are set and no control point has been programmed.
-
Please read the "Pre-programming the local Somfy io-homecontrol control point (§
2. 3. 2
)" section then the
"Registering the first local Somfy io-homecontrol control point (§
2. 3. 5 A
) section.
Reaction 2:
The motorised product does not move up and down when under voltage and does not react when the
control point keys are pressed.
-
The travel end limits are not set and no io control point has been programmed.
-
Go to the section Pre-programming the local Somfy io-homecontrol point (§
2. 3. 2
).
Reaction 3:
The motorised product does not move up and down when under voltage but does react when the control
point keys are pressed.
Commissioning is complete
.
230 V
50 Hz
L N
OFF
1)
2)