22
Copyright © 2016 Somfy SAS. All rights reserved.
Opening and impact "learning" mode
This enables the opening and impact sensor to recognise:
- an intrusion attempt: impact "learning"
This is accomplished through the following 3 steps (closed
window):
1) Press the calibration button (C) and hold for 3 seconds.
2) The red indicator light will light up for 10 seconds: close the
unit cover whilst the light is on.
3) The red indicator light will blink rapidly: this is the learning
step.
- Impact "learning": force/shake the door/window to simulate
an intrusion attempt.
If there is an error, the red indicator light will blink twice
every five seconds.
Carry out an intrusion or intrusion attempt test once this
stage is finished to check that the opening and impact
sensor is functioning correctly.
C
C
P