12
fan starts again for a period of 15 min after that time, if the temperature does not
reach the Set Point value of "VALV M" the fan switches off. To start the fan again, it
will be necessary to give the order manually.
Figure 10 – Display
7 – To change the Pump Set Point on the controller, press the "MENU (P1)" button
once, the Set Point value of the pump appears (the controller has a serial Set Point
of 60°C), press the "+ (P2)" or "- (P3)" button to increase or decrease the Set Point
temperature (it is recommended to set the Set Point value greater than or equal to
60°C), to return to the initial menu simply press the "MENU (P1)" button 3 times.
8 – To change the fan Set Point (VALV M) on the controller, press the "MENU (P1)"
button three times, the set point value of "VALV M" appears (the controller has a
serial set point of 60°C), press the "+ (P2)" or "- (P3)" button to increase or decrease
the set point temperature (it is recommended to set the set point value greater than
or equal to 60°C), to return to the initial menu simply press the "MENU (P1)" button
once.
To turn the controller off, press the "ON/OFF (P4)" button until the OFF led is turned
on, to turn the controller back on, press the "ON/OFF (P4)" button again until the
boiler temperature appears.
Button
MENU
Button
ON/OFF
Led
VENTILATOR
Led PUMP
Led “OFF”